28 Installation
(for qualified installers only)
© Travis Industries
9/25/17-1468
Maestro
Wiring the Power Vent (continued)
In addition to the exhaust blower line, a low-voltage wire harness is routed from the fireplace to the
damper inside the power vent assembly (see page 6 for wire lengths and part numbers).
Route the exhaust damper wire harness to the
junction box on the power vent assembly. Remove
the junction box cover plate. Remove the strain
relief from the cover plate (see illustration below to
the right). Route the wires through the slot on the
cover plate and replace the strain relief. Attach the
molex connector from the harness to the molex
connector inside the power vent assembly).
Exhaust Damper Molex Connector
Replace the junction box cover, making sure all
wiring is properly inserted.
Caution
:
Label all wires prior to disconnection
when servicing controls. Wiring errors
can cause improper and dangerous
operation.
Test blower operation after attaching the wiring (leave gas off, turn appliance on, verify blower
functions correctly).
Use pliers to compress the strain relief from the top
and bottom while pushing it into the hole in the bracket.