8
1. INTRODUCTION
Congratulations! You are now the proud owner of a high-performance ProMatic Salt Water Chlorinator. Please read
all information in this manual carefully before installing and operating your ProMatic system. Failure to follow these
instructions could increase your maintenance costs and also invalidate the manufacturer’s guarantee.
IMPORTANT!
TO ENSURE YOUR UNIT WORKS EFFECTIVELY, FOLLOW THE PROCEDURES BELOW:
> Prior to putting it into operation, make sure the pool water is properly balanced (pH, TAC, TH),
then distribute the salt in the water in the pool.
> When using the unit, check the cell regularly and clean it as and when necessary.
> Check that salt content is at 4g/Litre Minimum –(Max: 7g/Litre)
2. THE EQUIPMENT
A complete unit includes the following:
•
Power Supply / Control unit
•
Electrolytic Cell
•
Electrical connection cables
•
2 x 50mm Euro Barrel Unions
•
1 x Cell adaptor
•
1 x Cell Earth Bolt assembly
•
Mounting Kit & spare fuse
2.1 The Control Unit
The following features are located on the face of the unit
•
ON/OFF Switch
•
Fuse
•
Production indicator
•
Production control dial
•
Spring Mode switch
2.2 The Cell
The cell body is transparent so as to make it easier to check the electrodes for calcium scale and dirt build-up. The
electrodes, which are made of precious materials, are used to electrolyse the salt water in the pool.
2.3 The Connection Cables
These have the following functions:
•
To connect the switch cupboard to the output of the filter unit power supply unit (230V single phase + earth);
•
To supply low voltage to the cell;
•
To connect the safety device (gas detector).
Electrical Characteristics:
•
230V – 50Hz
•
220 – 240V / 50Hz-60Hz (MPS50CE only)
•
IP 34
•
Fuse 3A – for MPS16-24
•
Fuse 5A- for MPS36 - 50
MAX POWER
MPS 16 = 120 W
MPS 24 = 170 W
MPS 36 = 300 W
MPS 40 = 360 W
MPS 50 = 360 W
For MPS50CE only
•
PowerSupply / Control Unit
•
Electrolytic cell for MPS50CE
•
1 x Cell adaptor (50mm)
•
1 x Cell earth bolt assembly
•
Mounting kit & spare fuse
•
2 x 80/50mm reducing socket
•
2 x 80mm nut
•
2 x 80mm socket
Summary of Contents for ProMatic MPS 16
Page 2: ......
Page 6: ...6...
Page 17: ...17 9 APPENDIX 1 Independent earth MPS50CE Cell...
Page 29: ...29 MPS50CE Cell...
Page 33: ...33 MPS50CE Zelle...
Page 53: ...53 ANEXO MPS50 Celula...
Page 65: ...65 9 ALLEGATO 1 MPS50 Celula...
Page 66: ...66 ProMatic Modelos MPS Manual de instalaci n y de mantenimiento ESPA OL...
Page 75: ...75 MPS50 Celula...