PRE-START UP PROCEDURE

Before operating your EcoMineral Pool Sanitiser System please ensure the following quantity of  

EcoMineral Salt (P/N: EMSALT-15) and EcoMineral Activator (P/N: EMACT-15) has been added to your pool.

CONVERTING EXISTING SALT POOLS          NEW MINERAL SALT POOLS

Pool Size (Litres)

Davey Therapeutic 

EcoMineral Salt 

(15kg bags)

5,000 to 10,000

1 Bag = 15kg

10,001 to 20,000

2 Bags = 30kg

20,001 to 30,000

3 Bags = 45kg

30,001 to 40,000

4 Bags = 60kg

40,001 to 50,000

5 Bags = 75kg

50,001 to 60,000

6 Bags = 90kg

60,001 to 70,000

7 Bags = 105kg

70,001 to 80,000

8 Bags = 120kg

80,001 to 90,000

9 Bags = 135kg

90,001 to 100,000

10 Bags = 150kg

100,001 to 110,000

11 Bags = 165kg

110,001 to 120,000

12 Bags = 180kg

120,001 to 130,000

13 Bags = 195kg

130,001 to 140,000

14 Bags = 210kg

140,001 to 150,000

15 Bags = 225kg

1. Continue to operate your filter pump 

for a period of 24 hours following the 

addition of Davey EcoMineral Salt to 

ensure proper blending has occurred.

2. Davey EcoMineral Salt can be used 

with all Davey Salt Water Chlorinators 

with recommended TDS levels of 

between 4,000 and 6,000ppm.

3. When replacing normal pool salt with 

Davey EcoMineral Salt, ensure that 

TDS levels do not exceed 6,000ppm 

after its addition to the pool.

4. Ensure pH levels are between 7.4 & 7.6 

after the addition.

1. With the filter pump running, pour the contents of Davey 

EcoMineral Salt and Davey EcoMineral Activator into the  

pool evenly around the edge.

2. Continue to operate the filter pump for a period of  

24 hours following the addition to ensure proper blending  

has occurred. 

3. It is recommended that TDS levels be maintained between 

4,000 and 6,000ppm.

4. When using the Davey EcoMineral Salt and Davey 

EcoMineral Activator, ensure that TDS levels do not exceed 

6,000ppm after its addition to the pool.

5. Ensure pH levels are between 7.4 & 7.6 after the addition.

Note: When the need arises to top up your pool with Davey EcoMineral Salt or Davey EcoMineral Activator, due to dilution through rainfall 

or backwashing. Davey recommends you use equal quantities of EcoMineral Salt to Activator (ratio 1:1) and that you maintain your TDS 

level between 4,000 and 6,000ppm. This will ensure your mineral pool water stays soft, silky and crystal clear.

After adding Davey EcoMineral Salts to your pool the water may temporarily have discolouration and form clusters of foam on the 

surface. This is completely normal and is part of the mineralisation stage and transformation process. This may last for 24 hours, 

however after this time, your pool will return to normal and become crystal clear and clean. It is recommended that you run your filter 

pump for a minimum 24 hours after the addition of Davey EcoMineral Salts.

Pool Size (Litres)

Davey Therapeutic 

EcoMineral Salt 

(15kg bags)

Davey EcoMineral 

Activator  

(15kg bags)

5,000 to 10,000

1 Bag = 15kg

2 Bags = 30kg

10,001 to 20,000

2 Bags = 30kg

5 Bags = 75kg

20,001 to 30,000

3 Bags = 45kg

7 Bags = 105kg

30,001 to 40,000

4 Bags = 60kg

9 Bags = 135kg

40,001 to 50,000

5 Bags = 75kg

12 Bags = 180kg

50,001 to 60,000

6 Bags = 90kg

14 Bags = 210kg

60,001 to 70,000

7 Bags = 105kg

16 Bags = 240kg

70,001 to 80,000

8 Bags = 120kg

19 Bags = 285kg

80,001 to 90,000

9 Bags = 135kg

21 Bags = 315kg

90,001 to 100,000

10 Bags = 150kg

23 Bags = 345kg

100,001 to 110,000

11 Bags = 165kg

26 Bags = 390kg

110,001 to 120,000

12 Bags = 180kg

28 Bags = 420kg

120,001 to 130,000

13 Bags = 195kg

30 Bags = 450kg

130,001 to 140,000

14 Bags = 210kg

33 Bags = 495kg

140,001 to 150,000

15 Bags = 225kg

35 Bags = 525kg

Summary of Contents for EMX3600

Page 1: ...this equipment The installation of this product should be carried out by a person knowledgeable in swimming pool plumbing requirements following the installation instructions provided in this manual...

Page 2: ...he chlorination process Periodically check the safety flow switch to ensure it is free to move in the direction of flow as indicated by the arrow on the cell see Diagram A Always check Davey s website...

Page 3: ...POWER SUPPLY 6 PRE START UP PROCEDURE 7 OPERATION OF YOUR ECOMINERAL SYSTEM 8 CONTROL PANEL LAYOUT 9 ECOMINERAL SPECIAL FEATURES 10 AUTOMATIC TIME CLOCK OPERATION 11 MAINTENANCE OF POWER SUPPLY 13 MAI...

Page 4: ...ar monitoring of the electrolytic cell is recommended The Cell is the clear plastic housing containing the plates During the sanitisation process a white powdery Calcium scale may naturally build up o...

Page 5: ...d ventilation is necessary for correct operation Return to pool line Suction Line PUMP FILTER ACCESSORIES IN LINE CELL FLOW SWITCH POWER SUPPLY 240V Two self tapping screws and wall plugs have been pr...

Page 6: ...to the outer titanium rods Fit the white connector to the middle titanium rod as per illustration below EMX2400 EMX3600 NOTE The EcoMineral Cell is supplied with a paddle type flow switch which is to...

Page 7: ...the terminal holes at right angles and tighten the terminals CONNECTING THE FILTER CIRCULATION PUMP TO THE POWER SUPPLY Insert the 3 pin male plug into the 3 pin female socket located at the bottom o...

Page 8: ...0ppm 4 When using the Davey EcoMineral Salt and Davey EcoMineral Activator ensure that TDS levels do not exceed 6 000ppm after its addition to the pool 5 Ensure pH levels are between 7 4 7 6 after the...

Page 9: ...ly for at least 24 hours or until a reading of 3 ppm is reached STABILISER It is essential that pool stabiliser be added and maintained at the rate of 30 50 ppm at all times Do not exceed 100 ppm FOR...

Page 10: ...w Note Polarity LED may be either A or B whichever is on or brightest The RED Operation LED will indicate a number of different possible problem situations Possible Problem Action TDS Level Below Mini...

Page 11: ...the TDS level in the pool decreases the wear on the Cell increases Although EcoMineral Salt and Activator is not consumed in the sanitisation process it is lost through splashing backwashing and on ba...

Page 12: ...ong as the selector switch remains at this position Use the up and down buttons to reach the desired times Hold the buttons down for fast increments Set Timer 1 ON 2 SET THE START TIME FOR THE FIRST R...

Page 13: ...uction to change time Automatic ON 6 FILTRATION SYSTEM SWITCHES ON AND OFF AUTOMATICALLY ACCORDING TO YOUR SET TIMES Select the Automatic ON position on the selector switch A number 6 will appear on t...

Page 14: ...chlorite for an extended period Calcium in the plaster surfaces of a concrete pool Because these conditions vary so much check the Cell at least weekly to begin with to see when either scale or a blue...

Page 15: ...cale is being dissolved from the plates the solution will foam when this foaming action has stopped the Cell is clean and the solution can be returned to the container for future use or discarded appr...

Page 16: ...that you put salt directly in the skimmer box This is a very poor practice as it allows very high concentrations of salt to be passed through your filtration and other pool equipment EcoMineral Salt a...

Page 17: ...Control can be turned anti clockwise Test your chlorine level again the following morning at around the same time If your chlorine level is still high repeat the above process until the correct level...

Page 18: ...l by rain wind and dust There are numerous varieties some are free floating whilst others grow on walls and in cracks and come in different colours Some are more resistant to chemical treatment than o...

Page 19: ...ng 6 Sanitiser fuse blown 7 Dirty Cell 8 Filter needs back washing 9 Flow switch not connected 10 Insufficient water flow through cell 11 Running times incorrect 12 Main house fuse blown 13 Pump motor...

Page 20: ...eplacement of product consumables i e seals bearings or capacitors loss or damage resulting from misuse or negligent handling improper use for which the product was not designed or advertised failure...