TROUBLESHOOTING
Production Bar Meter
Operation LED
Reason/Action
Off
Green
• Start-up delay functioning;
• System control dial set below MAX. Cell is turned off.
(Refer operations on page 14)
5 LEDs
Green
• System operating normally
Less than 5 LEDs
Orange
• Salt level could be low. Get tested by your pool shop,
or service technician.
• Cell is calcified. Clean cell.
• Water temperature low < 25ºC (77ºF). Add salt to
compensate or heat water. Maintain salt level
between recommended level. (See page 4).
Off
Red
• Insufficient flow. Check pump & pipes for damage or
blockage and ensure that all valves to and from the
pump are open;
• Check flow switch connecting and working;
• Gas sensor not connected to cell.
• Salt level too low and cell has turned off.