background image

Page 26

8.

ADV. OPTIONS

- - - -

(SUBMENU)

(

)

(

)

(ESC)

(

)

(

)

- - - -

ADV OPTIONS

Push 8

1. HEAT CONTROL
2. HIGH HT OFFS
3. FILT. PERIOD*
4. FILT. TIME*

(SET)

(

)

(

)

O.50

1. HEAT CONTROL

Scroll to SET

1. SET TEMP
2. USER TIMER
3. CLOCK
4. USER ALARM
5. SLEEP TIMES
6. MAINT TIMERS
7. MISC OPTIONS

9. LD. DEFAULTS

8. ADV. OPTIONS

*N/A circulation pump installations

Select MAIN menu then push UP button 8 times

7.8.7 Panel And Pool Light Synchronisation (on/off)

The SP1200 touch pad backlight has the ability to mirror the colour and intensity of the in-pool Spa Power Variable
Colour Light (SPVCL). This feature is most noticeable when a light effect mode is being used and the light colour is
changing rapidly.

When the pool light is turned off the touch pad backlight will remain one user selectable fixed colour. If desired the
synchronising/mirroring feature can be disabled and the touch pad backlight will remain on the fixed colour even
when the pool light is turned on.

7.8.8 Enabling/Disabling Light Synchronisation

7.9 Advanced Options Submenu

The advanced options menu contains settings that should only be modified after you are familiar with the basic
operation of the spa. The defaults will generally be satisfactory and will probably not need to be changed.

1) Select the MISC OPTIONS submenu from the main menu.
2) Select the PANEL & POOL LT. SYNC menu item
3) Press the SCROLL button modify light synchronisation setting
4) Use the UP and DOWN buttons to toggle between on and off
5) Press the SCROLL button to set.

Note: This option is only available if a SPVCL (Spa Power Variable Colour Light) is in the pool.

Page 7

3.3 Pump 1

(Two speed, 24HR circulation pump fitted)

This pump is controlled via two touch pad buttons - one to turn the pump on/off and another to change its speed.
The mode and pump speed selected by these buttons are shown for a few seconds on the LCD display as well as
being indicated by the pump button LEDs. The two pump button LEDs are green, red or off when the pump is on-
low, on-high or off.

Two pushes of the on/off button cycles the pump as follows:

Two pushes of the on/off button cycles the pump as follows:

Notes:
1) If left on, these pumps will automatically switch off after 25 minutes.
2) If the heater element is on, running either pump in high speed mode may cause the heater to load shed and

switch off. If this occurs the heater will come back on approximately 5 seconds after high speed is deselected
(pump running in low speed or pump off).

Pump 1

Pump 2

Push 1

(Pump On)

Push 2

(Pump Off)

LCD displays “PUMP OFF”, button LEDs off. The Hi/Low speed button has no effect in this mode.

Push 1

(Pump Hi)

Push 2

(Pump Low)

The Hi/Low speed button can be used to change the pump speed:

Push 1

(Pump On)

Push 2

(Pump Off)

LCD displays “PUMP OFF”, button LEDs off. The Hi/Low speed button has no effect in this mode.

Push 1

(Pump Hi)

Push 2

(Pump Low)

The Hi/Low speed button can be used to change the pump speed:

Summary of Contents for SPI200 Series

Page 1: ...to the above values to ensure a healthyexperiencebothforyouasbathersandforyourspapoolequipment Damage to the element thermostat pockets and associated metalwork due to the poor maintenanceofwaterchem...

Page 2: ...ll a problem then contact your spa pool supplier Error 6 THERMAL CUT OUT Thermal Cut Out Tripped This error indicates that the safety electromechanical over temperature cut out on the heater has opera...

Page 3: ...detected in the heater housing On a push of the DOWN button the main pump will run for 10 seconds to try to get water to the heater If successful normal operation will resume If unsuccessful the erro...

Page 4: ...g any water in the heater housing If no water is being detected the LCD Display will also show WATER PRIMING PLEASE WAIT Heater This LED shows when the heater is on The heater will turn on and off as...

Page 5: ...touch pad LCD contrast brightness can be manually adjusted if the display appears too dark or light To adjust the contrast follow these steps 1 Press and hold down the LIGHT button This will cycle the...

Page 6: ...on please see section 3 9 LD DEFAULTS SET NO ARE YOU SURE Push 9 Scroll to SET NO YES 1 SET TEMP 2 USER TIMER 3 CLOCK 4 USER ALARM 5 SLEEP TIMES 6 MAINT TIMERS 7 MISC OPTIONS 8 ADV OPTIONS 9 LD DEFAUL...

Page 7: ...hour to ensure filtration times are met similarly a setting of 4 hours indicates that a filtration run will occur once every 4 hours 1 Select the ADV OPTIONS submenu from the main menu 2 Select the F...

Page 8: ...the controller will attempt to use the high setting whenever heating is required Note that high heat may not always be available due to possible load shedding when accessories are turned on depends on...

Page 9: ...ton modify light synchronisation setting 4 Use the UP and DOWN buttons to toggle between on and off 5 Press the SCROLL button to set Note This option is only available if a SPVCL Spa Power Variable Co...

Page 10: ...of touch pad inactivity no button presses the backlight intensity will automatically return to a fixed 34 setting This is to ensure long life of the backlight LEDs As soon as you press a button on th...

Page 11: ...touch pad inactivity The Air Button controls a Spa Power Variable Speed Blower if fitted It is used to turn the blower on off and select different operating modes Four pushes of the air button cycle t...

Page 12: ...o SPVCL is fitted then the buttons can still be used to produce lighting effects on the touch pad as though a light was fitted The Light Level button selects the intensity of the light and the Light E...

Page 13: ...he available colours one at a time without any smooth fading between different colours The UP and DOWN buttons may be used to change the speed of the light effect see section 6 2 1 below LCD Displays...

Page 14: ...play Notes 1 For correct sleep operation ensure the clock is set correctly You will need to set it the first time the controller is powered up or if the controller has been turned off for a long perio...

Page 15: ...s Options Menu and Advanced Options Menu These sub menus are accessed via main menu items 4 to 8 respectively Simply select one of these items in the main menu and press the SCROLL button You will now...

Page 16: ...ry handy feature that is used to silence the spa pool during your hours of sleep While the SP1200 is asleep no automatic heating or filtration maintenance will occur however the spa can still be used...

Page 17: ...timer by pressing SCROLL again Otherwise wait approximately five seconds for the message to disappear and you will be returned back to the default view with the timer running in the background 7 4 Clo...

Page 18: ...USER TIMER 3 CLOCK 4 USER ALARM 5 SLEEP TIMES 6 MAINT TIMERS 7 MISC OPTIONS 8 ADV OPTIONS 9 LD DEFAULTS Page 17 Select MAIN menu then push UP button four times 7 5 User Alarms The SP1200 controller h...

Reviews: