background image

7.

MISC OPTIONS

- - - -

(SUBMENU)

(

)

(

)

(ESC)

(

)

(

)

- - - -

MISC.

OPTIONS

Push 7

1. KEY CLICKS
2. MAIN DISPLAY

5. PANEL & POOL LIGHT SYNC*
*Only available if a SPVCL is
fitted to pool

3. PANEL LIGHT COLOUR
4. PANEL LIGHT INTENSITY

Scroll to SET

(CHANGE)

(

)

(

)

1. KEY

CLICKS

1. SET TEMP
2. USER TIMER
3. CLOCK
4. USER ALARM
5. SLEEP TIMES
6. MAINT TIMERS

8. ADV. OPTIONS
9. LD. DEFAULTS

7. MISC OPTIONS

Page 24

- - - -

Select MAIN menu then push UP button 7 times

7.8 Miscellaneous Options Submenu

The miscellaneous options menu contains convenience options that primarily allow you to customise the look of the
poolside touch panel. None of the options have any effect upon the basic spa control functions such as pump
operation or heating.

7.8.1 Key Clicks (on/off)

By default the touch pad will beep whenever a button is pressed, however key clicks (beeps) may be turned on and off
as desired using the procedure below:

1) Select the MISC OPTIONS submenu from the main menu.
2) Select the KEY CLICKS menu item
3) Press the SCROLL button
4) Use the UP and DOWN buttons to toggle between on and off
5) Press SCROLL button to set

Note: Disabling key clicks will not silence user timer beeps etc.

Up

Down

Page 9

3.6 24Hr Circulation Pump On/Off

If a circulation pump has been fitted the spa manufacturer may have assigned an on/off button on the touch pad to
turn the circulation pump on and off. If a button has been assigned follow the instructions below.
-To switch circulation pump off push the assigned button.
-To switch the circulation pump on push the assigned button.

5 Spa Power Variable Speed Blower (SPVSB)

Note:
If the circulation pump is switched off it will be reactivated after 25 minutes of touch pad inactivity.

The Air Button controls a Spa Power Variable-Speed Blower (if fitted). It is used to turn the blower on/off and select
different operating modes.

Four pushes of the air button cycle the blower as follows:

5.1 Adjustable Speed Mode (SPVSB)

In the adjustable speed mode the UP and DOWN buttons are used to set the blower to one of 9 different speeds.
On the first press of UP or DOWN the LCD will display “BLOWER SPEED” along with a bar graph showing the
current speed setting. While viewing this display you may press the UP and DOWN button to adjust the speed as
required. Hold down either button for automatic key press repeat. This setting is saved and will be automatically
restored next time you select the adjustable speed mode.

Notes:
1) The UP and DOWN buttons are shared with Light Level, Light Mode, SPVSB speed and the menu system.

When not within the menu system the actual use of the UP and DOWN buttons depends on which of the three
function buttons was pressed last - Light Level, Light Mode or Air.

4 Auxillary On/Off (pump, blower, light)

Two pushes of the Auxilary button cycles the outlet as follows:

Push 1

(Aux On)

Push 2

(Aux Off)

LCD displays “Aux Off”, button LED off.

LCD displays “Aux On”, button LED green.

Notes:
1) If Aux is left on, this oulett will automatically switch off after 25 minutes.
2) If the heater element is on, running this outlet may cause the heater to load shed and switch off. If this occurs

the heater will come back on approximately 5 seconds after the pump is deselected.

Push 1

(Blower On)

Push 2

(Blower Ramping)

Push 3

(Blower Speed)

Push 4

(Blower Off)

LCD Displays “BLOWER ON HIGH”, Blower on
full speed

LCD Displays “BLOWER OFF”, (Default State)

LCD Displays “BLOWER SPEED” and bar graph
Showing actual speed setting, Blower on adjustable
speed (see below)

LCD Displays “BLOWER RAMPING”, speed oscillating

Summary of Contents for SPI200 Series

Page 1: ...to the above values to ensure a healthyexperiencebothforyouasbathersandforyourspapoolequipment Damage to the element thermostat pockets and associated metalwork due to the poor maintenanceofwaterchem...

Page 2: ...ll a problem then contact your spa pool supplier Error 6 THERMAL CUT OUT Thermal Cut Out Tripped This error indicates that the safety electromechanical over temperature cut out on the heater has opera...

Page 3: ...detected in the heater housing On a push of the DOWN button the main pump will run for 10 seconds to try to get water to the heater If successful normal operation will resume If unsuccessful the erro...

Page 4: ...g any water in the heater housing If no water is being detected the LCD Display will also show WATER PRIMING PLEASE WAIT Heater This LED shows when the heater is on The heater will turn on and off as...

Page 5: ...touch pad LCD contrast brightness can be manually adjusted if the display appears too dark or light To adjust the contrast follow these steps 1 Press and hold down the LIGHT button This will cycle the...

Page 6: ...on please see section 3 9 LD DEFAULTS SET NO ARE YOU SURE Push 9 Scroll to SET NO YES 1 SET TEMP 2 USER TIMER 3 CLOCK 4 USER ALARM 5 SLEEP TIMES 6 MAINT TIMERS 7 MISC OPTIONS 8 ADV OPTIONS 9 LD DEFAUL...

Page 7: ...hour to ensure filtration times are met similarly a setting of 4 hours indicates that a filtration run will occur once every 4 hours 1 Select the ADV OPTIONS submenu from the main menu 2 Select the F...

Page 8: ...the controller will attempt to use the high setting whenever heating is required Note that high heat may not always be available due to possible load shedding when accessories are turned on depends on...

Page 9: ...ton modify light synchronisation setting 4 Use the UP and DOWN buttons to toggle between on and off 5 Press the SCROLL button to set Note This option is only available if a SPVCL Spa Power Variable Co...

Page 10: ...of touch pad inactivity no button presses the backlight intensity will automatically return to a fixed 34 setting This is to ensure long life of the backlight LEDs As soon as you press a button on th...

Page 11: ...touch pad inactivity The Air Button controls a Spa Power Variable Speed Blower if fitted It is used to turn the blower on off and select different operating modes Four pushes of the air button cycle t...

Page 12: ...o SPVCL is fitted then the buttons can still be used to produce lighting effects on the touch pad as though a light was fitted The Light Level button selects the intensity of the light and the Light E...

Page 13: ...he available colours one at a time without any smooth fading between different colours The UP and DOWN buttons may be used to change the speed of the light effect see section 6 2 1 below LCD Displays...

Page 14: ...play Notes 1 For correct sleep operation ensure the clock is set correctly You will need to set it the first time the controller is powered up or if the controller has been turned off for a long perio...

Page 15: ...s Options Menu and Advanced Options Menu These sub menus are accessed via main menu items 4 to 8 respectively Simply select one of these items in the main menu and press the SCROLL button You will now...

Page 16: ...ry handy feature that is used to silence the spa pool during your hours of sleep While the SP1200 is asleep no automatic heating or filtration maintenance will occur however the spa can still be used...

Page 17: ...timer by pressing SCROLL again Otherwise wait approximately five seconds for the message to disappear and you will be returned back to the default view with the timer running in the background 7 4 Clo...

Page 18: ...USER TIMER 3 CLOCK 4 USER ALARM 5 SLEEP TIMES 6 MAINT TIMERS 7 MISC OPTIONS 8 ADV OPTIONS 9 LD DEFAULTS Page 17 Select MAIN menu then push UP button four times 7 5 User Alarms The SP1200 controller h...

Reviews: