Setting Up

6

ergo_memo-card2

Protection

slider

Safety button

18 levels

Vertical adjustment
Loosen the spring loaded tommy head button  

2

  by one to two turns, and then

pull it out. Move the saddle column up or down to the required height. Release

the tommy head button and move the saddle column a little bit up or down until

the protruding red safety button on the tommy head button locks in. Then tighten

the tommy head button.

For safety reasons height adjustment is only possible up to level 18!

360° continuous

Switching ON / Off

Please read the safety notes before switching the ergo_bike premium8 on, and

follow the installation and assembly instructions.
Insert the ergo_memo-card2 in the dashboard before switching the device on.
Use the On/Off switch  " I " on the lower rear section of the device to switch it

on and off.

3

2

13cm

1

Handlebars adjustment

Loosen the star knob  

3

  adjust the handlebars to the required position and

tighten the star knob back.

On / Off power switch

Saddle adjustment

Horizontal adjustment
Loosen the lever  

1  

 slide the saddle to the required position and then tighten

the lever again.

The lever should point to the rear after tightening. Pull and turn the lever to point

to the rear.

- risk of injury.

When switched on, the system takes about 1 minute to load the software. The

colour  screen  displays  during  this  time  a  software  load  progress  bar.
Wait for the beep signal before using the dashboard.
If the memory card is inserted after the Premium device is switched on, then

you must wait for the beep signal. This can take about 5 seconds. (if the card

is empty it will be initialised)
In principle the memory card should be pulled out while you are not pedalling

or only after the beep signal!
The protection slider on the ergo_memo-card2 must point to the bottom when

the card is inserted into the dashboard. This will make it possible to write to the

card.
If the slider points upward the card is locked/write protected.

If the card is empty it will be initialised. Only then can you use a computer to

save e.g. mp3 files (in the \mp3 folder) or update files (in the \update folder) on

the card. 

The maximal cards size is to 1GByte.

Notes to the handling of SD cards (page 16)
In the case of a commercial use (whenever the device is used frequently on a

daily basis) we recommend switching it ON in the morning and then switching

it OFF once at evening.

Wireless Pulse rate Measure

The ergo_bike medical8 is equipped with a Polar receptor module, and can thus

receive coded pulse rate signals only.

Summary of Contents for ergo_bike medical8

Page 1: ...medical Operating Instructions 0650682e 0004 0297...

Page 2: ...tting Personal Data 8 Starting Training by Selecting a Program 9 Training Programs 9 10 Setting Limit Values 10 11 Reviewing Stored Training Data 11 MP3 Player 12 Keywords Glossary 12 General Notes Im...

Page 3: ...de come into contact with others conductive parts including the grounding while getting on the ergo_bike medical8 Please do never touch device parts conducting very low safety voltage and the patient...

Page 4: ...estion from the device When providing a diagnosis the results must always be controlled and evaluated by a qualified physician The electronic installations of the rooms where the device will be used m...

Page 5: ...rs 3 Handlebars continuously adjustable over 360 4 Clamp screw for the handlebars 5 Roller casters 6 Name plate 7 Potential equalisation 8 On Off switch 9 Height adjustment for the saddle 10 Saddle co...

Page 6: ...ightening Pull and turn the lever to point to the rear risk of injury When switched on the system takes about 1 minute to load the software The colour screen displays during this time a software load...

Page 7: ...d gear The value that can be actually modified will be colour highlighted in the training view 11 Audio connector Used to connect a headphone 12 Card reader for the ergo_memo card2 Underside 13 Reset...

Page 8: ...ys Use the info key to obtain more information about the individual menu items If the requested information spans many pages you can leaf through the pages by turning the control button Press the Info...

Page 9: ...e With the RPM controlled programs the wheel speed in revolutions per minute is maintained at a level defined by the user Training Programs Pulse Rate Training Programs With the pulse rate programs th...

Page 10: ...or before setting the loading values after a few training units Dynamic Limit Values and Static Limit Values can be set Due to their natural variability dynamic limit values are continually exceeded S...

Page 11: ...ton to select Setting Turn and press control button to select Personal data Turn and press control button to Select Training Unit Turn and press control button to Select Diagram Reviewing Stored Train...

Page 12: ...rol button to start playing the selected title The system continues with playing all the music titles eventually following the selected one in the list The volume is controlled by means of the 2 dedic...

Page 13: ...should still be slightly bent at the lower pedal position Fig A as for normal biking as opposed to the racing posture Fig B Environmental Conditions Ergometers are not suited for operation in areas o...

Page 14: ...n Issue EN 1041 Informationen supplied by the manufacturer 1998 with medical devices EN 60601 1 A1 A2 Medical electrical equipment Part 1 General 1996 requirements for safety EN 60601 1 2 Medical elec...

Page 15: ...plate located on the housing with your local supply voltage prior to plugging the power cord to the power supply Please contact you dealer if the values are not the same The device is completely disco...

Page 16: ...for operating medical products and the known technical regulations and be repaired as needed Technical safety tests may only be executed by persons technicians with the proper education and knowledge...

Page 17: ...upervision duty verified II Functions ON OFF switch verified EMERGENCY STOP device verified Controls mechanical verified Controls dashboard console verified III User manual The user manual was read an...

Page 18: ...heet for the testing before placing into service and repeat testing of medical electrical devices or systems according to GEF German Electrotechnology Federation 0751 1 Next test date Remark Tester Si...

Page 19: ...ty of medical products at daum electronic gmbh The device must be tested according to GEF German Electrotechnology Federation 0751 1 before it is put back into service Failure description Spare part I...

Page 20: ...and only if you received the program in object code or executable form with such an offer in accord with Subsection b above The source code for a work means the preferred form of the work for making m...

Page 21: ...distribution limitation excluding those countries so that distribution is permitted only in or among countries not thus excluded In such case this License incorporates the limitation as if written in...

Page 22: ...f any to sign a copyright disclaimer for the program if necessary Here is a sample alter the names Yoyodyne Inc hereby disclaims all copyright interest in the program Gnomovision which makes passes at...

Page 23: ......

Page 24: ...daum electronic gmbh Flugplatzstr 100 D 90768 F rth Tel 49 0 911 97536 0 Fax 49 0 911 7537 14 www daum electronic de Stand 25042007...

Reviews: