Safety Notes

3

Using the Device in Compliance with the Recommendations

The ergometers of the ergo_bike medical8 series may be used exclusively for

ergometry,  cardiovascular  rehabilitation  and  for  kinesitherapy.

Their use is only allowed in compliance with the directions of the operating

instructions.

The manufacturer will not be held liable if the ergometer is not used in compliance

with the provided instructions and consequently causes injury to persons or

other severe consequences, as well as material damages.

The ergo_bike medical8 carries the CE label CE 0297 according to the council’s

directive for medical products 93/42 EEC and complies with the basic requirements

of appendix 1 of this directive.

The  CE  label  covers  only  the  accessories  included  in  the  package.

Every user of this device and everyone who is concerned with assembling,

maintaining, testing or troubleshooting it, must read and understand the contents

of  this  operating  instructions  before  starting  to  work  on  the  device.

The quality assurance system used at daum electronic gmbh complies with the

DIN EN ISO 13485:2003 standard.

The ergo_bike medical8 are designed according to the MPG, group IIa and

comply with the corresponding type B, according to DIN EN 60601-1:1996.

The devices comply to the safety and health requirements according to:

93/42/EEC  of  the  council  of  June  14,  1993  about  medical  products,

DIN EN 60601-1-2:2001 (EU directive about electromagnetic compatibility).

daum electronic gmbh considers itself to be liable for the safety, reliability and

functionality of the device only if:

- Modifications and repairs to the device are carried out by daum electronic

  gmbh or by a service provider formally authorised by daum electronic gmbh

  to do this work.

- the device is used in compliance with the directions of the operating instructions.

Personnel (Staff)

The ergo_bike medical8 may only by operated by educated personnel (staff).

The personnel must read and understand this operating instructions before

operating the device.

The operating instructions must be kept in the direct vicinity of the ergo_bike

medical8.

Patient Safety

According to the prescriptions of the by-law (order) for operating medical products

(MP by-law §5) the users must

- be educated in operating the ergometer.

- master the necessary sequences for handling and assembling the device.

- know the applicable safety regulations for operating this type of devices, and

  act accordingly.

- know about any additional regulations that may apply (e.g. safety facilities).

- know about possible risks (hazards) that may arise from using this type of

  devices.

In order to maintain the safety of the patients, it must be avoided that conductive

parts and the connectors connected to them, including the neutral electrode,

come into contact with others conductive parts (including the grounding), while

getting on the ergo_bike medical8.

Please do never touch device parts conducting very low safety voltage and the

patient simultaneously.

When coupling with other devices or with a combination of medical systems

care must be taken to prevent any danger arising from the summation of the

leakage currents. If you have any questions please ask your dealer or the service

department of daum electronic gmbh. In particular, when coupling many devices

to a test site care must be taken to ensure that the potential equalisation is

effected through a common power supply (e.g. a wall socket-outlet).

If a socket with multiple outlets is installed after the initial start-up, no other

device may be connected to this socket. (use covers on the multiple sockets)

An electrical shock hazard exists when touching non-medical devices, and

devices that are not separately grounded.

Defective or faulty devices and accessories may not be used.

The personal computer and all other connected non-medical devices (e.g.

monitor, printer, etc) must be installed at least 1.5m away from the patient place,

because leakage currents could be generated on the housing (or use separate

grounding, housing leakage current).

Patient Treatment

All the devices and the related components and parts must every time be

checked for functionality and defects before they are used with the patient.

Notes From the Manufacturer to the User

The  device  is  not  protected  against  the  infiltration  of  liquids.

Direct  contact  with  humidity  or  liquids  must  absolutely  be  avoided.

Care must be taken to wipe out sweat drops after training (sweat attacks paint

and plastic parts)

Damages  caused  by  sweat  are  not  covered  by  the  warranty.

The ergometer should be installed on a level, firm floor (e.g. concrete

floors). For other floor surfaces we recommend to use the device over a

protective underlay. Appropriate underlays for the protection of the floor

can be ordered from daum electronic gmbh.

The  manufacturer  will  not  be  held  liable  for  damages  to  the  floor.

Order No. 0810401

Accessories

The device may only be used with the accessories prescribed and distributed

by daum electronic gmbh.

Every accessory item and every device connected must be manufactured in

conformity with the corresponding standard, e.g. DIN EN 60950 for computer

devices, DIN EN 60601-1 for electromedical devices.

Software

The supplied software may only be copied and archived for safety and functional

reasons. In special cases a request must be addressed in writing to daum

electronic gmbh. Releasing it to non-authorised persons in not allowed. The

ergo-bike medical8 may only be used with the internal and external softwares

supplied and authorised by daum electronic gmbh.

Documentation

The documentation supplied is an integral part of the ergo_bike medical8 and

may only be copied or distributed with the authorisation of daum electronic

gmbh.

GB

Summary of Contents for ergo_bike medical8

Page 1: ...medical Operating Instructions 0650682e 0004 0297...

Page 2: ...tting Personal Data 8 Starting Training by Selecting a Program 9 Training Programs 9 10 Setting Limit Values 10 11 Reviewing Stored Training Data 11 MP3 Player 12 Keywords Glossary 12 General Notes Im...

Page 3: ...de come into contact with others conductive parts including the grounding while getting on the ergo_bike medical8 Please do never touch device parts conducting very low safety voltage and the patient...

Page 4: ...estion from the device When providing a diagnosis the results must always be controlled and evaluated by a qualified physician The electronic installations of the rooms where the device will be used m...

Page 5: ...rs 3 Handlebars continuously adjustable over 360 4 Clamp screw for the handlebars 5 Roller casters 6 Name plate 7 Potential equalisation 8 On Off switch 9 Height adjustment for the saddle 10 Saddle co...

Page 6: ...ightening Pull and turn the lever to point to the rear risk of injury When switched on the system takes about 1 minute to load the software The colour screen displays during this time a software load...

Page 7: ...d gear The value that can be actually modified will be colour highlighted in the training view 11 Audio connector Used to connect a headphone 12 Card reader for the ergo_memo card2 Underside 13 Reset...

Page 8: ...ys Use the info key to obtain more information about the individual menu items If the requested information spans many pages you can leaf through the pages by turning the control button Press the Info...

Page 9: ...e With the RPM controlled programs the wheel speed in revolutions per minute is maintained at a level defined by the user Training Programs Pulse Rate Training Programs With the pulse rate programs th...

Page 10: ...or before setting the loading values after a few training units Dynamic Limit Values and Static Limit Values can be set Due to their natural variability dynamic limit values are continually exceeded S...

Page 11: ...ton to select Setting Turn and press control button to select Personal data Turn and press control button to Select Training Unit Turn and press control button to Select Diagram Reviewing Stored Train...

Page 12: ...rol button to start playing the selected title The system continues with playing all the music titles eventually following the selected one in the list The volume is controlled by means of the 2 dedic...

Page 13: ...should still be slightly bent at the lower pedal position Fig A as for normal biking as opposed to the racing posture Fig B Environmental Conditions Ergometers are not suited for operation in areas o...

Page 14: ...n Issue EN 1041 Informationen supplied by the manufacturer 1998 with medical devices EN 60601 1 A1 A2 Medical electrical equipment Part 1 General 1996 requirements for safety EN 60601 1 2 Medical elec...

Page 15: ...plate located on the housing with your local supply voltage prior to plugging the power cord to the power supply Please contact you dealer if the values are not the same The device is completely disco...

Page 16: ...for operating medical products and the known technical regulations and be repaired as needed Technical safety tests may only be executed by persons technicians with the proper education and knowledge...

Page 17: ...upervision duty verified II Functions ON OFF switch verified EMERGENCY STOP device verified Controls mechanical verified Controls dashboard console verified III User manual The user manual was read an...

Page 18: ...heet for the testing before placing into service and repeat testing of medical electrical devices or systems according to GEF German Electrotechnology Federation 0751 1 Next test date Remark Tester Si...

Page 19: ...ty of medical products at daum electronic gmbh The device must be tested according to GEF German Electrotechnology Federation 0751 1 before it is put back into service Failure description Spare part I...

Page 20: ...and only if you received the program in object code or executable form with such an offer in accord with Subsection b above The source code for a work means the preferred form of the work for making m...

Page 21: ...distribution limitation excluding those countries so that distribution is permitted only in or among countries not thus excluded In such case this License incorporates the limitation as if written in...

Page 22: ...f any to sign a copyright disclaimer for the program if necessary Here is a sample alter the names Yoyodyne Inc hereby disclaims all copyright interest in the program Gnomovision which makes passes at...

Page 23: ......

Page 24: ...daum electronic gmbh Flugplatzstr 100 D 90768 F rth Tel 49 0 911 97536 0 Fax 49 0 911 7537 14 www daum electronic de Stand 25042007...

Reviews: