Specifications

EC manufacturer's declaration of conformity

15

Safety Requirements

daum electronic gmbh hereby declares that this product complies with the

following provisions regarding electromagnetic compatibility and electrical safety:

- EN 957-5 Additional specific safety requirements and test methods
- EC directive 93/42EEC of the council of June 14, 1993 about medical products
- 89 / 336 / EEC of May 3, 1989 including subsequent changes (Recommendation

  92 / 31 / EEC of April 28, 1992 and recommendation 93 /68 / EEC of July 22,

 1993)
- 73 / 23 / EEC of February 19, 1973 including subsequent changes

  (Recommendation 93 / 68 / EEC of August 30, 1993)
-  02 / 96 / EG of January  27, 2003 about Recycling of old electic and electronic

devices

-  03  /  108  /  EG  of  December  8,  2003  of  changes  (Recommendation)

   2002 / 96/ EG 

about Recycling of old electic and electronic 

- EN 60601-1-2 (EMC, Generic Emission Standard, Part 1: Residential commercial

  and light industry)

Technical Safety Recommendations:

Compare the supply voltage indicated on the nameplate located on the housing

with your local supply voltage prior to plugging the power cord to the power

supply. Please contact you dealer if the values are not the same.

The device is completely disconnected from the power supply by pulling out the

power cord, therefore it should always be plugged into an easily accessible

socket.

Braking system:

                 Computer-controlled, full electronic eddy current

                                                   brake (operating in the speed ranges shown

                                                   in the diagram on page 16)

Load range:

                 20 to 1000 Watt

Speed range:

                 0 to 200 RPM

Load precision:

                 Conform to DIN VDE 0750-238 (German

                                                    Electrotechnology Federation)

Loading levels:

                 In 1-Watt increments, manually adjustable

Drive:

                 Two-stage, maintenance-free V-ribbed belt drive.

Saddle height adjustment:           fast setting in 18 levels

Handlebars setting:                  approx. 360° continuous

Displays:                                   Colour screen

                                                    256 Colours

                                                    320 x 240 / 76800 Pixels

Pulse rate measurement:

Measuring range 40 to 200 beats per minute

                                                    Telemetric using the Cardio sensor chest strap

                                                    (available as an optional accessory)

Alarm signals:

Acoustic and optical

Weight:                                     approx. 45 kg

Dimensions:

                 L 97 cm, W 54 cm, and H 125 cm

Power supply:

230 V alternating current, 50 Hz, 50 VA

protective signs:

                 CE - 0297

Safety class:

                 1

GB

Summary of Contents for ergo_bike medical8

Page 1: ...medical Operating Instructions 0650682e 0004 0297...

Page 2: ...tting Personal Data 8 Starting Training by Selecting a Program 9 Training Programs 9 10 Setting Limit Values 10 11 Reviewing Stored Training Data 11 MP3 Player 12 Keywords Glossary 12 General Notes Im...

Page 3: ...de come into contact with others conductive parts including the grounding while getting on the ergo_bike medical8 Please do never touch device parts conducting very low safety voltage and the patient...

Page 4: ...estion from the device When providing a diagnosis the results must always be controlled and evaluated by a qualified physician The electronic installations of the rooms where the device will be used m...

Page 5: ...rs 3 Handlebars continuously adjustable over 360 4 Clamp screw for the handlebars 5 Roller casters 6 Name plate 7 Potential equalisation 8 On Off switch 9 Height adjustment for the saddle 10 Saddle co...

Page 6: ...ightening Pull and turn the lever to point to the rear risk of injury When switched on the system takes about 1 minute to load the software The colour screen displays during this time a software load...

Page 7: ...d gear The value that can be actually modified will be colour highlighted in the training view 11 Audio connector Used to connect a headphone 12 Card reader for the ergo_memo card2 Underside 13 Reset...

Page 8: ...ys Use the info key to obtain more information about the individual menu items If the requested information spans many pages you can leaf through the pages by turning the control button Press the Info...

Page 9: ...e With the RPM controlled programs the wheel speed in revolutions per minute is maintained at a level defined by the user Training Programs Pulse Rate Training Programs With the pulse rate programs th...

Page 10: ...or before setting the loading values after a few training units Dynamic Limit Values and Static Limit Values can be set Due to their natural variability dynamic limit values are continually exceeded S...

Page 11: ...ton to select Setting Turn and press control button to select Personal data Turn and press control button to Select Training Unit Turn and press control button to Select Diagram Reviewing Stored Train...

Page 12: ...rol button to start playing the selected title The system continues with playing all the music titles eventually following the selected one in the list The volume is controlled by means of the 2 dedic...

Page 13: ...should still be slightly bent at the lower pedal position Fig A as for normal biking as opposed to the racing posture Fig B Environmental Conditions Ergometers are not suited for operation in areas o...

Page 14: ...n Issue EN 1041 Informationen supplied by the manufacturer 1998 with medical devices EN 60601 1 A1 A2 Medical electrical equipment Part 1 General 1996 requirements for safety EN 60601 1 2 Medical elec...

Page 15: ...plate located on the housing with your local supply voltage prior to plugging the power cord to the power supply Please contact you dealer if the values are not the same The device is completely disco...

Page 16: ...for operating medical products and the known technical regulations and be repaired as needed Technical safety tests may only be executed by persons technicians with the proper education and knowledge...

Page 17: ...upervision duty verified II Functions ON OFF switch verified EMERGENCY STOP device verified Controls mechanical verified Controls dashboard console verified III User manual The user manual was read an...

Page 18: ...heet for the testing before placing into service and repeat testing of medical electrical devices or systems according to GEF German Electrotechnology Federation 0751 1 Next test date Remark Tester Si...

Page 19: ...ty of medical products at daum electronic gmbh The device must be tested according to GEF German Electrotechnology Federation 0751 1 before it is put back into service Failure description Spare part I...

Page 20: ...and only if you received the program in object code or executable form with such an offer in accord with Subsection b above The source code for a work means the preferred form of the work for making m...

Page 21: ...distribution limitation excluding those countries so that distribution is permitted only in or among countries not thus excluded In such case this License incorporates the limitation as if written in...

Page 22: ...f any to sign a copyright disclaimer for the program if necessary Here is a sample alter the names Yoyodyne Inc hereby disclaims all copyright interest in the program Gnomovision which makes passes at...

Page 23: ......

Page 24: ...daum electronic gmbh Flugplatzstr 100 D 90768 F rth Tel 49 0 911 97536 0 Fax 49 0 911 7537 14 www daum electronic de Stand 25042007...

Reviews: