![Datcon DT9502 Operating Instructions Manual Download Page 82](http://html1.mh-extra.com/html/datcon/dt9502/dt9502_operating-instructions-manual_3748132082.webp)
DT9502
82
20171205-V3
The limit output may work in Alarm mode too. This mode is
switched ON by the
parameter. According to the
default factory setting it is switched off (
). When the
Alarm mode is ON (
), the limit output switches on when
it has to switch on according to the measured and displayed
physical value, but it will not switch off even if the value
changes so that it should cause it to switch off. The output
can be switched off by pressing the
ENTER
button only
(acknowledgement).
Alarm mode
Of course, if the condition that causes the output to switch
on persists, the limit output will switch on again when the
ENTER
button is released.
(Similary to working of fire-alarm gear generates fire alarm.
Not suffice to definitive liquidation receipt signal alarming,
but must liquidate fire, generative cause.
After switching on the instrument
After switching on the instrument the limit outputs are
disabled as long as it performs at least three measurements
necessary for a complete averaging. This takes a few
seconds maximum. In this way can be avoid false signalling
due to transients that may appear in the measuring loop.
Summary of Contents for DT9502
Page 1: ...DT9502 Intrinsically Safe Temperature Meter Transmitter Operating Instructions ...
Page 64: ...DT9502 64 20171205 V3 10 2 Application example ...
Page 84: ...DT9502 84 20171205 V3 10 9 ATEX Certification ...
Page 85: ...DT9502 20171205 V3 85 ...
Page 86: ...DT9502 86 20171205 V3 ...
Page 87: ...DT9502 20171205 V3 87 ...
Page 88: ...DT9502 88 20171205 V3 ...
Page 89: ...DT9502 20171205 V3 89 ...
Page 90: ...DT9502 90 20171205 V3 ...
Page 91: ...DT9502 20171205 V3 91 ...
Page 92: ......