2-18
001-4006-101
Tx Frequency
Tx Frequency displays the transmit frequency for the channel pair.
Power
Power displays the Power Output Adjust value for the channel pair. The default value is 255 (5 watts). This
value should be left at the default value unless:
z
a lower power is required to meet regulatory requirements or
z
the user’s application requires an increase in the transmit duty cycle
Default Freqs
The Default Freqs button forces the Rx and Tx Frequencies to their default values, based on radio type and
range.
2.5.5 VERSION REQUEST
Selecting Version Request causes the T-96SR Field Programming Software to display information about the
version of the T-96SR hardware and firmware.
Figure 2-13 Version Request Screen
2.5.6 WRITING / READING T-96SR PARAMETERS
After all radio parameters are setup, select the OK button to store the information into the PC’s
memory. To load parameters into the T-96SR, initiate a Write Programmable Settings from the
Edit menu or select the Write icon from the Tool Bar
.
After the programmable parameters are
loaded into the T-96SR, save the parameter information using the Save Data As option in the File
pull-down menu.The name and location of the file (*.dat extension) will appear on the status bar at the
bottom of the screen.
Note:
The “Clone Programmable Parmeters” feature should be used instead of the
“Write Programmable Parameters” whenever multiple radios are being programmed with identical
parameters.
The Read Programmable Settings command will read parameters from the current T-96SR and
store the information in local memory. The parameters can be viewed and/or edited with the
Setup Modem/Radio Parameters screens.
Note: Dataradio recommends a Read be done anytime an initial connection is made to the T-96SR Setup
Port before accessing the Setup Modem/Radio Parameters screen. This will help avoid writing erroneous
parameters to the connected unit.
2.02