2-14
001-4006-101
Note: If 9 Data Bits, 2 Stop Bits is selected, Remote Diagnostics or Commands are not supported and
Online Diagnostics must be disabled for proper network data operation.
Important: All units in a network
must use the same Data Format setting.
2.5.4.2 Data Type
Data Type behavior is dependent on the modem connected to the user PC.
z
Connected to a T-96SR Modem operating in “T-96SR Native” network type: Enhanced Only Data Type
z
Connected to a T-96SR Modem operating in “T-96S/DL3276” (or Crystal) network type: Enhanced
or
Compatible Data Type
Note: Choose “Compatible” if the modem is to be used with RNet 9600S (crystal) or T-Modem96 (crystal)
units with serial numbers below 103500. The buffer icon to the right of his option will turn to an inverting
buffer when “Compatible” is selected. Choose “Enhanced” for other applications to achieve better
performance.
Important: All units in a network must use the same Data Format setting.
2.5.4.3 Network Type
Interdependent with Baud Rate and Data Type, Network Type allows over-the-air compatibility and varies
according to the products used in the network. Network Type is dependent on the modem connected to the
user PC.
Figure 2-9 Network Type Connected to a T-96SR Modem
Figure 2-10 Network Type Connected to T-96S/DL3276
z
Connected to a T-96SR Modem, Network Types include:
1.T-96SR Native: available Baud Rate options include 4800/9600/19200 for full-channel units or 4800/
9600 for a half-channel units. Data Type is Enhanced Only