3.5 PRELIMINARY STEPS
Important Note: Before proceeding make sure that the service monitor has been calibrated recently and
has warmed up for at least the time specified by its manufacturer. Some reported frequency and deviation
problems have actually been erroneous indications from service monitors that have not adequately warmed up.
This is particularly likely when field service is done during winter months.
1. Connect the Integra-H antenna connector to the radio service monitor RF input using a 023-3410-118 or
equivalent 50-ohm cable. That input should be able to support at least 1 watt.
2. Connect Integra-H to the power supply and adjust the supply voltage to 13.3 volts.
WARNING: Do not exceed 16 VDC during setting-up for tests and adjustments.
3. Using a 9-conductor straight RS-232 cable, connect the unit's Setup port to the RS-232 port of a PC and
run the Integra RSS program (INTRSS.exe) on the PC.
4. Press GET for the unit configuration.
5. From the Settings menu command, click on Radio Settings, set the frequency to be used for testing. Leave
this window open and on top.
6. Follow the steps in Table 7.
3.5.1 AFTER ADJUSTMENTS ARE COMPLETED
Adjustments made using the RSS are temporary and must be made permanent as follows:
1. After all adjustments are completed satisfactorily, press “PUT” to save the changes permanently
to the unit.