MODEL 2000 PRINTER
OPERATION AND MAINTENANCE
DataMetrics Corporation
25
4.3. Self Test
The self test function will print 5 lines of each resident font and then print the draft font for
approximately 20 minutes. The self test function is initiated by activating the prime power
switch while pressing the LF/FF switch. The test sequence can be terminated prior to
completion by powering down the printer.
4.4. Normal Operation
Follow the instructions defined below to operate the printer under normal conditions.
a. Power-up the host computer.
b. Place the printer power switch in the “on” position and verify that the control panel
POWER indicator is illuminated.
c. The printer can be configured to enter the on-line state manually or automatically using
the Setup Utility (Table 3-1). Once the printer has achieved an on-line state, no
manual intervention is required to conduct routine print tasks. Operational parameters
are not affected by normal power on/off cycles.
4.4.1. Stopping a Print Job
A print job can be terminated from the host computer or at the printer control panel. Place
the printer off line to stop a print job from the control panel. Unprinted data in the buffer can
be cleared by cycling printer power. If power is not cycled, the print job will continue when
the printer is returned to the on-line state.
4.5. Error Conditions
Refer to Chapter 6 for information concerning printer troubleshooting and corrective action.
4.6. Shutdown
It is not necessary to power down the printer when the unit is not used for limited periods.
When the printer is to be taken out of service, perform the following shutdown sequence:
a. Ensure that the printer is not receiving data from the host computer.
b. Place the printer power switch in the “off” position.
Summary of Contents for 2000 Series
Page 2: ......
Page 4: ......
Page 8: ......
Page 12: ...MODEL 2000 PRINTER OPERATION AND MAINTENANCE DataMetrics Corporation 4 ...
Page 34: ...MODEL 2000 PRINTER OPERATION AND MAINTENANCE DataMetrics Corporation 26 ...
Page 46: ......