Chapter 3 - Printer Operation
29
Advanced Entry Calibration (continued)
Step
Action
Displayed Message
Comment
L
Use the buttons to set the Gain
Number determined in the
previous step. Press ENTER to
enable the setting.
TRAN SENSOR GAIN
yyy (0 - 31)
18
This example uses Gain Number
18.
M
Complete a table (see example
below) using new measurements,
as follows:
(A) Raise the Printhead Assembly.
Place the label over the Media
Sensor then lower and latch the
Printhead Assembly. Record the
sensor reading as P.
(B) Raise the Printhead Assembly.
Place the liner, notch, or mark
over the Media Sensor then lower
and latch the Printhead Assembly.
Record the sensor reading as G (or
M).
(C) Raise the Printhead Assembly.
Remove all media from the Media
Sensor then lower and latch the
Printhead Assembly. Record the
sensor reading as E.
TRAN SENSOR GAIN
yyy (0 - 31)
18
Where “yyy” is a numerical value
representing the current sensor
reading.
The re-sampled values may
differ from those previously
noted. This is normal; do not
readjust the Media Sensor.
Selected Gain Table
Gain Number
Paper
Gap (or Mark)
Empty
18 173 42 9
Summary of Contents for I-Class Mark II I-4212E/203
Page 1: ...Operator s Manual...
Page 2: ......
Page 8: ...Chapter 1 Getting Started 2...
Page 20: ...Chapter 2 Printer Setup 14...
Page 38: ...Chapter 3 Printer Operation 32...
Page 62: ...Chapter 4 Menu System 56...
Page 76: ...Chapter 6 Troubleshooting 70...
Page 80: ...Appendix A Specifications 74...
Page 88: ...Appendix B Wireless and Wired LAN Setup 82...
Page 94: ......