Chapter 3 - Printer Operation
24
Standard Calibration (continued)
Step
Action
Displayed Message
Comment
F
Proceed according to the media
type:
All media except Continuous –
Position label material (and liner, if
any) over the sensor then press
the ESC Key.
Continuous – Install media.
Position the Media Sensor under
the stock and press ESC.
SCAN PAPER
PRESS ESC KEY
yyy
This sets the paper value, where
“yyy” represents the current
sensor reading.
(1) If using preprinted media,
ensure that the area placed over
the sensor is free of text,
graphics, or borders.
(2) See Section 2.3 for sensor
adjustment instructions.
G
Observe the calibration result.
CALIBRATION COMPLETE
Calibration was successful.
If WARNING LOW BACKING is
displayed, calibration was
successful.
H
Press ESC then EXIT to return to
READY.
When calibrating gap or reflective
media, press and hold the FEED
Key until at least one label is
output.
CALIBRATION COMPLETE
Followed by...
READY
The printer is now ready for use.