VLASE
TM
IR
50
4
4 USE AND OPERATION
4.1 TURNING ON SEQUENCE
Before turning on the marking system, be sure that the system is connected as previously described. Check
presence of voltage power supply connection, interlock connector and Command Box connector. Check that
KEY
and
ENABLE
commands on the rack front panel are disabled (see Figure 19 and Figure 20).
1
ST
:
turn on the main switch at the back of the control rack:
Figure 54: Power on.
SIGNAL
STATUS
EXT_KEY
OFF
EXT_ENABLE_A
OFF
EXT_ENABLE_B
OFF
During booting-up, the status LED on the rack front panel will be blinking green.
Wait until booting-up finishes. The status LED on the rack will be steady green.
Figure 55: Status LED display
.