SAFETY CONSIDERATION ACCORDING TO EN ISO 13849-1:2008
82
UNIQ™
Safety Logic diagram suitable for a DC=90%
Characteristics of components
DOOR SWITCH:
SAFETY INTERLOCK SWITCH, designed in compliance with the standard
currently in effect IEC60947, EN292, EN60204, EN1088. Two redundant contacts. IP67.
B10d=2000000.
SAFETY LOGIC:
main component SAFETY PLC min. PLd according EN13849-1. Output
type relays, min 10mA. To be installed in an IP54 enclosure.
Conclusions
Safety Function of this example meets the quantitative requirements of PLr = e.