TECHNICAL SPECIFICATIONS
24
UNIQ™
SHUTTER_OUT signals behavior
OPEN
OPEN
CLOSED
CLOSED
SAFE
DANGEROUS
SHUT_OUT_A
LASER
SHUT_OUT_B
MARKER
< 500 ms
DELAY
TIME
< 500 ms
DELAY
TIME
< 500 ms
DELAY
TIME
< 500 ms
DELAY
TIME
Figure 14: SHUTTER_OUT signals behavior
Electric diagram
SHUTTER OUT
ENABLE OUT
USER SIDE
USER SIDE
LASER MARKER SIDE
LASER MARKER SIDE
Figure 15: Shutter OUT/Enable OUT connector electric diagram
Shutter OUT cable
Connector type SWITCHCRAFT TA Series Tini Q-G (Mini XLR) pre-wired female connec-
tor, 6 positions.
Figure 16: Pre-wired female plug connector code TA6FLX)
NOTE: The response time is 500ms from the input's switching.