SAFETY CONSIDERATION ACCORDING TO EN ISO 13849-1:2008
78
UNIQ™
Example automatic production line
In this case the Protective Housing may have a guard capable of being opened or
removed, typically only for service operation (frequency: seldom or occasional):
•
Guard opening should only be possible with the aid of a tool.
•
Guard interlock is connected as input of a safety logic (e.g. safety PLC) and UniQ™
interlock system as output/input of that PLC.
•
Warning label for access panel according EN60825-1 must be applied.
DANGER
Since the frequency is LOW (F1) and the removal of the guard is intentional, the MINI-
MUM REQUIREMENT as per IEC13849-1 is PLc.
Target: PLr = c
Severity of injury (S)
S1
Slight (normally reversible injury)
S2
Serious (normally irreversible injury or death)
Frequency and/or exposure time to hazard (F)
F1
Seldom to less often and/or exposure time is short
F2
Frequent to continuous and/or exposure time is long
Possibility of avoiding hazard or limiting harm (P)
P1
Possible under specific conditions
P2
Scarcely possible
INSPECTION
GUARD