The serial Datalogic Transfer
Protocol Server (DTPS) has been
run through the related “ds.bat”
command but it cannot
communicate with other Datalogic
client application programs
running on PC side (WinDTP or
DL Mobile Configurator™).
Check whether one of the following conditions has
occurred:
- the RS232 parameter settings of the DTPS
program do not correspond to the settings of the
program running on the PC. The DTPS
transmission speed is 115.200 bps (for further
details refer to the DTPS, WinDTP or DL Mobile
Configurator™ manuals);
- Rhino™ has been connected to the PC through a
wrong cable.
After updating the Flash image,
Rhino™ does not work properly
(boot sequence not completed,
Rhino™ lock).
If the Flash image has been updated with a new image
having a different dimension, ensure that Disk C: is
formatted by using the FFDISK command (refer to the
DL Flash Loader manual for further details).
If problem persists, repeat both the Flash updating
procedure and the Disk C: formatting, and ensure that
all disk C: files have been reinstalled correctly (refer to
the DL Mobile Configurator™ manual for further details
about restoring Disk C: on Rhino™).
In case the problem still persists, contact your nearest
Datalogic distributor for technical assistance.