MESSAGE FORMATTING
197
[Code len]
The optional Code len formatting. It can be programmed:
•
from General Data Format, represented in the following
as
[C len]
•
from specific Data Format Display and Keypad
Parameters, represented in the following as
[S len]
[C Header] [Scanner_Addr] [Scanner_Addr delimiter] [Cradle_Addr] [Cradle_Addr_
delimiter] [Time Stamp ][Time Stamp Delimiter]
[ S Header]
[Code ID] [Ccode len]
CODE
[S Terminator]
[C Terminator ]
Code ID, Code Length and Code can be different content in the 16-key DK model.
These features can be programmed with Scanner Data Header/Terminator on page
149, or Keypad Data Header/Terminator on page 151.
Field code ID and Code length may also be programmed in the DK model:
[C Header] [Scanner Addr] [Scanner Addr delimiter] [Cradle Addr] [Cradle Addr
delimiter] [Time Stamp ][Time Stamp Delimiter]
[ S Header]
[C ID] [C len]
CODE
[S Term]
[C Term ]
[C Header] [Scanner Addr] [Scanner Addr delimiter] [Cradle Addr] [Cradle Addr
delimiter] [Time Stamp ][Time Stamp Delimiter]
[ S Header]
[S ID] [S len]
CODE
[S Term]
[C Term ]
The prefix C means programmed from general Data Format beginning on page 69,
and the prefix S means it is programmed from Scanner Code ID and Scanner Code
Length in Display and Keypad for 16-keys, on page 153.
NOTE:
in case of double formatting for
[Code ID] [Ccode len],
only one of these is
included in message formatting. Specific Data Format
[S ID] [S len]
takes priority over
general Data Format.
The code field
[CODE]
as additional formatting in the 16-key model, when the device
is programmed in Qty/Code mode.
Summary of Contents for PowerScan D8300