Enter Configuration
Exit and Save Configuration
Ì$+;Î
16-KEY DK MODEL PARAMETERS
Ì$-?Î
149
SCANNER DATA HEADER/TERMINATOR
Scanner Data Header/Terminator creates an optional Header and Terminator data format
added to a barcode read from the device.
NOTE:
Keyboard data format enable/disable (on previous page) must be used to enable the
Header and Terminator setup, so the two parameters should be combined to get the desired
result.
HEADER
no header
one character header
two character header
three character header
four character header
five character header
six character header
seven character header
eight character header
After selecting
one
of the desired Header codes, read the character(s) from the HEX table.
Valid characters are in the range
00-FE
. For Wedge and USB-KBD interfaces, it is also possible
to read the
Special Key(s)
on page 74.
Example
:
Four character header
Hex codes
Header
Read
+
41 + 42 + 43 + 44
=
ABCD
For more details see par. 5.4.1 and par. 5.4.2. See also “Message Formatting” in par. 6.1 and
6.2.