Enter Configuration
Exit and Save Configuration
Ì$+;Î
16-KEY DK MODEL PARAMETERS
Ì$-?Î
143
FUNCTION KEY LABEL
This item allows the user to change the default mnemonic label associated to each individual
function key (F1 – F4). This is done by programming a short acronym string or symbol to be
shown in the bottom of the display. The purpose of the label is to serve as an indication of the
programmed function of the Function Key below it. To program the Function Keys themselves,
see the “Function Key Programming” command on page 141.
NOTE
: Function key label length is fixed at 4 characters and is not programmable.
define function key label
Read the above code.
Specify which Function Key Label you want to change by scanning a barcode (1-4) from the
hex numeric table in the back of this manual.
Define the label string by scanning 4 characters from the Hex numeric table.
Example
:
To define Function Key 2 label = D
Define function key
label
Function
key #
Hex codes
Text string
Read
+
2
+
20 + 20 + 44 + 20
=
space space D space
LOWER CASE
This function enables/disables the capability to use the SHIFT key to switch to Lower Case
(alphanumeric) mode. When enabled, the indication in the upper right corner of display is ‘ab’.
Disable Lower Case
Enable Lower Case