POWERSCAN
®
D8330/M8300/M8300-DK
28
5.
Set Radio Address
ÌRA0RFHÎ
+
four digits for the PowerScan
®
M8300 Address (from
0000
to
1999
).
All readers used in the same area must have different addresses.
6.
Exit and Save Configuration
Ì$-?Î
7.
Read the
Bind
code to pair the PowerScan
®
M8300 to the BC-80X0 cradle.
The reader is dedicated to the cradle. Any previously
bound
reader will be
excluded.
To connect several readers to the same cradle see the following paragraph
4.5.1, ‘Using Multiple M8300 Series Readers with Same Cradle'.
Bind
Ì$+RN0$-IÎ
The green LED on the PowerScan
®
M8300 will blink; the reader is ready to be
inserted into the cradle.
8.
Firmly insert the reader into the BC-80X0 cradle within 10 seconds, a beep will
be emitted, signaling that the BC-80X0 cradle has been paired to the
PowerScan
®
M8300, and the green LED on the reader will go off.
green LED