F-4
Magellan
®
9500
UPC-E with 2-Digit Supplemental
•
Number system must be included in label data.
•
Check digit must be included in label data and is assumed to be cor-
rect.
•
Supplemental data is appended to base label.
•
Prefix must be an ASCII character 'E' - total length including prefix
must be 11.
•
Example: 'E0998875012'.
UPC-E with 5-Digit Supplemental
•
Number system must be included in label data.
•
Check digit must be included in label data and is assumed to be cor-
rect.
•
Prefix must be an ASCII character 'E' - total length including prefix
must be 14.
•
Example: 'E0998875012345'.
UPC-E with Code 128 Supplemental
•
Number system must be included in label data.
•
Check digit must be included in label data and is assumed to be cor-
rect.
•
Supplemental data is appended to base label.
•
Prefix must be an ASCII character 'E' - total length including prefix
must be greater or equal to 15 (code 128 Supplemental codes are
variable length having a minimum of 2 data characters).
•
Characters immediately following base label must be of the form
'8100', '8101' or '8102'.
•
Example: 'E099887508101000951'.