5-12
Magellan
®
9500
8. Place an additional 200 grams on the center of the weighing surface
and check that the display reads 1.000 kg.
9. Increase the weight on the scale to 7.50 kg on the center of the
weighing surface and check that the display reads between 7.495
and 7.505 kg.
10. Remove the weights and verify that the display reads 0.000 kg. You
have completed the Increasing-Load Test (Phase 1).
Shift Test (Metric)
The Shift Test checks to ensure that items placed anywhere on the weigh-
ing surface of the scanner/scale are weighed properly. Refer to
Figure 5-3
when performing this test.
1. Place and remove in succession, a 5.0 kilogram load on the center of
each of the four quadrants (A, B, C, and D in
Figure 5-3
) and in the
center of the scanner/scale’s weighing platform. Verify that the dis-
play shows a reading of between 4.995 and 5.005 kg for each quad-
rant/center test and that the display returns to 0.000 between each
load.
2. After verifying the accuracy of each quadrant and the center of the
weighing surface, remove all weight from the scale. You have com-
pleted the Shift Test.