6-36
Magellan
®
9500
Scale Enforced Zero Return
This feature enables/disables the enforced zero return of the scale. Three
settings are available for this feature:
•
Disable
•
Scale Must Return to Zero Weight Within Four Minutes — Scale
will require re-zeroing if a non-zero weight is left on for more than 4
minutes
•
Scale Must Return to Zero Weight Between Weight Requests — Re-
zeroing required if weight doesn't return to zero between weight
requests from the POS, plus scale will require re-zeroing if a non-
zero weight is left on for more than 4 minutes.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan your selection from the bar codes below. You’ll need to cover
any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan. The strategy is
to select the lowest possible filter level needed that allows normal
scale operation.
3. Complete the programming sequence by scanning the SWITCH
bar code.
SCALE ENFORCED ZERO RETURN = DISABLE