RS-232 Features
Product Reference Guide
6-87
RS-232 Hardware Control
Enables/disables use of the RS-232 CTS signal for flow control and/or
scan control.
Options are:
•
Disable — The scanner transmits to the host regardless of any activ-
ity on the CTS line.
•
Enable CTS Flow Control — The CTS signal controls transmission
of data to the host.
•
Enable CTS Scan Control — The CTS line must be active for scan-
ner to read and transmit data. While the CTS line is inactive, scan-
ner remains in a host- disabled state; following a successful label
transmission, the CTS signal must transition to inactive and then to
active to enable scanning for the next label.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan bar code below or from the following page for the desired set-
ting. You’ll need to cover any unused bar codes on facing pages to
ensure that the scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
RS-232 HARDWARE CONTROL = DISABLE