Product Reference Guide
F-3
UPC-A with 5-Digit Supplemental
•
Number system must be included in label data
•
Check digit must be included in label data and is assumed to be cor-
rect
•
Prefix must be an ASCII character 'A' - total length including prefix
must be 18
•
Example: 'A06099201118712345'
UPC-A with Code 128 Supplemental
•
Number system must be included in label data.
•
Check digit must be included in label data and is assumed to be cor-
rect.
•
Supplemental data is appended to base label.
•
Prefix must be an ASCII character 'A' - total length including prefix
must be greater or equal to 19 Code 128 Supplemental codes are
variable length having a minimum of 2 data characters).
•
Characters immediately following base label must be of the form
'8100', '8101' or '8102'.
•
Example: 'A0609920111878100000951'.
UPC-E
•
Number system must be included in label data
•
Check digit must be included in label data and is assumed to be cor-
rect
•
Prefix must be an ASCII character 'E' - total length including prefix
must be 9
•
Example: 'E09988750'
Summary of Contents for Magellan 9500 Omega
Page 1: ...Magellan 9500 9500 9504 9504 with SmartSentry Product Reference Guide...
Page 28: ...1 16 Magellan 9500 NOTES...
Page 100: ...4 14 Magellan 9500 NOTES...
Page 116: ...5 16 Magellan 9500 NOTES...
Page 396: ...6 280 Magellan 9500 NOTES...
Page 416: ...B 10 Magellan 9500 NOTES...
Page 426: ...D 2 Magellan 9500 NOTES...
Page 442: ...E 16 Magellan 9500 NOTES...
Page 458: ...F 16 Magellan 9500 NOTES...