![Datalogic DS5100-X200 Reference Manual Download Page 158](http://html.mh-extra.com/html/datalogic/ds5100-x200/ds5100-x200_reference-manual_511885158.webp)
DS5100 REFERENCE MANUAL
142
C
C CONNECTIONS FOR PROFINET-IO MODELS
ON-BOARD PROFINET-IO CONNECTORS (2)
Two Standard M12 D-Coded female connectors are provided for the on-board PROFINET-IO
connection. This interface is IEEE 802.3u 100 BaseTx compliant.
Use accessory ETH CABLE M12-M12 cables or Cat 5e or superior cables.
Figure 86 - M12 D-Coded 4-pin Female PROFINET-IO Network Connector
On-Board Ethernet Network Connector Pinout
Pin
Name
Function
1
TX +
Transmitted data (+)
2
RX +
Received data (+)
3
TX -
Transmitted data (-)
4
RX -
Received data (-)
POWER + INPUT (TRIGGER)
Figure 87 - M12 A-Coded 5-pin Male Power Connector
Power Connector Pinout
Pin
Name
Function
CS-A1-02
1
Vdc
Power supply input v
Brown
2
I1A
External Trigger Input (polarity insensitive)
White
3
GND
Power supply input voltage -
Blue
4
I1B
External Trigger Input (polarity insensitive)
Black
5
NC
Not Connected
nc
The CS-A1-02 or AS-I accessory power cables can be used to connect to the power source.
The CS-A1-02 cables can also be used to connect to the input trigger signal.
3
4
1
2
1
4
3
2
5
Summary of Contents for DS5100-X200
Page 1: ......
Page 30: ...DS5100 REFERENCE MANUAL 14 1 b Digital Outputs configuration c Hardware interface selection ...
Page 62: ...DS5100 REFERENCE MANUAL 46 3 Figure 18 DS5100 OM Serial Model Overall Dimensions ...
Page 78: ...DS5100 REFERENCE MANUAL 62 4 Figure 38 ID NET Network Connections with isolated power blocks ...
Page 97: ...TYPICAL LAYOUTS 81 5 7 Double click on the DS5100 scanner to configure it ...
Page 163: ...147 X X PRESS Human Machine Interface 23 ...
Page 164: ......