![Datalogic DS5100-X200 Reference Manual Download Page 107](http://html.mh-extra.com/html/datalogic/ds5100-x200/ds5100-x200_reference-manual_511885107.webp)
READING FEATURES
91
6
6.1.1 Tilt Angle for Advanced Code Reconstruction
The most important parameter in Advanced Code Reconstruction is the value of the
maximum tilt angle (
maximum) under which the code reconstruction process is still
possible.
Laser Beam
= tilt angle
0° to
max
Figure 72
– Tilt Angle
The decoder will be
able to
read
the label with a
tilt angle
between
+
max and -
max as shown in the following figure:
Conveyor
Laser Beam
No Read
No Read
-
+
0
°
OK
OK
OK
OK
OK
No Read
Figure 73
– Reading Zones with
Max