6.1.2 ACR Reading Conditions for Medium Range Models
The following tables describe the minimum code height requirements (
in mm
) for standard
ACR4 applications depending on the code symbology and the given reading conditions.
ANSI Grade B minimum
2/5 Interleaved
Minimum Code Height for ACR4 Reading (mm)
45° max
30° max
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.5
1
1.5
2
2.5
3
Code Resolution
(mm)
0.25
12 15 18 21 23 26
8
11 13 15 17 19
0.30
14 16 19 22 25 28
9
11 14 16 18 20
0.33
15 17 20 23 26 29 10 12 14 16 19 21
0.38
16 19 22 24 27 30 11 13 15 17 20 22
0.50
20 22 25 28 31 34 13 15 17 19 22 24
0.72
26 29 32 35 37 40 17 19 21 23 25 28
1.00
35 37 40 43 46 49 21 24 26 28 30 33
Ratio 3:1
Table 1
Code 39
Minimum Code Height for ACR4 Reading (mm)
45° max
30° max
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.5
1
1.5
2
2.5
3
Code Resolution
(mm)
0.25
11 14 16 19 22 25
8
10 12 14 16 19
0.30
12 15 18 20 23 26
8
10 13 15 17 19
0.33
13 16 18 21 24 27
9
11 13 15 18 20
0.38
14 17 20 22 25 28
9
12 14 16 18 21
0.50
17 20 22 25 28 31 11 13 16 18 20 22
0.72
22 25 28 31 33 36 14 16 19 21 23 25
1.00
29 32 35 37 40 43 18 20 23 25 27 29
Ratio 3:1; Interdigit = Module Size
Table 2
Code 128
– GS1-128
Minimum Code Height for ACR4 Reading (mm)
45° max
30° max
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.5
1
1.5
2
2.5
3
Code Resolution
(mm)
0.25
9
12 15 18 21 23
7
9
11 13 16 18
0.30
10 13 16 19 22 24
7
9
12 14 16 18
0.33
11 14 16 19 22 25
8
10 12 14 17 19
0.38
12 15 17 20 23 26
8
10 13 15 17 19
0.50
14 17 20 22 25 28
9
12 14 16 18 21
0.72
18 21 24 27 29 32 12 14 16 19 21 23
1.00
24 26 29 32 35 38 15 17 19 22 24 26
Table 3
Summary of Contents for DS5100-X200
Page 1: ......
Page 30: ...DS5100 REFERENCE MANUAL 14 1 b Digital Outputs configuration c Hardware interface selection ...
Page 62: ...DS5100 REFERENCE MANUAL 46 3 Figure 18 DS5100 OM Serial Model Overall Dimensions ...
Page 78: ...DS5100 REFERENCE MANUAL 62 4 Figure 38 ID NET Network Connections with isolated power blocks ...
Page 97: ...TYPICAL LAYOUTS 81 5 7 Double click on the DS5100 scanner to configure it ...
Page 163: ...147 X X PRESS Human Machine Interface 23 ...
Page 164: ......