LASER MARKER STATES
USER MANUAL
43
Error States
This state occurs if the laser marker detects an
error that prevents normal operation
Blinking
This error rise if the INTERLOCK function is ON. To reset the error, set
INTERLOCK function to OFF and repeat the turning on sequence
This error rise if the CONNECTOR_PRESENCE signal (pin 10 Com-
mand Box connector) is LOW or not connected. To reset the error, set
CONNECTOR_PRESENCE signal to HIGH value and repeat the turning
on sequence
This error rise if the temperature inside the control rack is out of the
operating temperature range. To reset the error, a Laser marker
restart is required
This error rise if the temperature inside the scan head is out of the
operating temperature range. To reset the error, a Laser marker
restart is required
This alarm rise if the cable between control rack and scan head is not
connected. To reset the error, a Laser marker restart is required
This error rise if the temperature inside the laser source is out of the
operating temperature range. To reset the error, a Laser marker
restart is required
This error rise if the power supply of the laser source is out of range.
To reset the error, a Laser marker restart is required
This error rise if high optical power is reflected back to the laser
source. To reset the error, a Laser marker restart is required
This error rise if the laser source detects an internal failure. To reset
the error, a Laser marker restart is required
Warning State
This state occurs if the turning on sequence has
not been followed. To restore normal laser marker
operation, repeat the turning on sequence
Blinking
STATE
DESCRIPTION
STATUS LED
ERROR
SYSTEM ERROR
DESCRIPTION
INTERLOCK ERROR
CBOX ERROR
RACK TEMPERATURE
ERROR
SCANHEAD
TEMPERATURE ERROR
SCANHEAD
CONNECTION ERROR
LASER SOURCE
ERRORS
DESCRIPTION
TEMPERATURE ERROR
POWER SUPPLY ERROR
BACK REFLECTION
ERROR
GENERIC ERROR
STATE
DESCRIPTION
STATUS LED
WARNING INVALID
START SEQUENCE