Manual Datafox KYO Inloc
page 64
date: 16.12.2020 Version: 04.03.15.XX
5.7.4.2. One bus for access-control, 5 relays in the KYO Inloc
Cable plan for 5 doors, 5 relays in the KYO Inloc:
Reader table for this example:
ID
ZM / Bus-ID
TM (Busadress)
RefLocation
RefAction
PinGeneral
description
1
1
010
1
1
0
reader / RS485 Busadress 1 / Bus ID 1
2
1
020
2
2
0
reader / RS485 Busadress 2 / Bus ID 1
3
1
030
3
3
0
reader / RS485 Busadress 3 / Bus ID 1
4
1
040
4
4
0
reader / RS485 Busadress 4 / Bus ID 1
5
1
050
5
5
0
reader / RS485 Busadress 5 / Bus ID 1
6
1
320
0
1
0
AC-Box V4 (Master device)
TCP / IP (LAN)
M1
SIM
GPRS
GPS
M3
Relais
ZK
HK
Variante mit RS485 Haupt-
kommunikation
RS 485 AC Bus-ID 1
Busadresse 1
door
relay 1 in
the AC-Box
12 V DC- power supply for
the access control reader
door
relay 2 in
the AC-Box
door
relay 3 in
the AC-Box
door
relay 4 in
the AC-Box
door
relay 5 in
the AC-Box
R
S
4
8
5
R
S
4
8
5
R
S
4
8
5
R
S
4
8
5
Busadresse 2
Busadresse 3
Busadresse 4
Busadresse 5