Manual Datafox KYO Inloc
page 60
date: 16.12.2020 Version: 04.03.15.XX
5.7.4. Wiring variants for the KYO Inloc
The KYO Inloc can be optionally equipped with up to 3 access control bus connections RS485.
This results in a variety of connection variants for setting up an access control system.
5.7.4.1. Wiring in a star form of the access control for the KYO Inloc
Cable plan for 3 doors and 3 relays in the KYO Inloc:
! Recommand for new intallations.
Reader table for this example:
ID
ZM / Bus-ID
TM (Busadresse) RefLocation
RefAction
PinGeneral Description
1
1
010
1
1
0
Reader on RS485
Bus-ID 1
2
2
010
2
2
0
Reader on RS485
Bus-ID 2
3
3
010
3
3
0
Reader on RS485
Bus-ID 3
4
1
320
0
1
0
AC-Box V4 (Master-device)
Wiring plan for one of the AC-control line RS485 / EVO-Intera-Reader:
(
all 3 lines of the access control have the same structure
)
TCP / IP (LAN)
M1
SIM
GPRS
GPS
M3
Relais
ZK
HK
Variante mit RS485 Haupt-
kommunikation
RS 485 AC
Bus-ID 1
RS 485 AC
Bus-ID 2
RS 485 AC
Bus-ID 3
Bus Nr. 1
Bus Nr. 1
Bus Nr. 1
Door opener relay 1 in the AC-Box
Door opener relay 2 in the AC-Box
Door opener relay 3 in the AC-Box
12V supply
+
-
max. 30 V / 2A
Power supply for the door opener
Bus No. 1
EVO-AC-Reader
Supply12 V DC for the AC-Reader
-
+
; 3A
plug 4 poles
for AC-Bus
module slot 1
plug 5 poles
for digital in/out