![Datacom DM991C Product Manual Download Page 82](http://html.mh-extra.com/html/datacom/dm991c/dm991c_product-manual_511542082.webp)
Product Manual - DM991 Series V Family - 204.4092.08
82
Power
input(V)
Maximum
consumption (mA)
+5
700
+12
200
-12
150
Table 24. Current Maximum Consumption - DM991S/SE
19.3.2. DM991C/CE
Power is supplied to the equipment through a power tri polar cable terminated with a three-prong plug.
The power cord can be plugged onto any AC outlet, within the specified limits (Table 25), the selection is
automatically done. If DC power is used, the AC plug should be cut and plugged in a way that the central
pin correspond to the protection ground and then the plugging should be done according to Figure 38.
The converter chassis is grounded by the protection ground.
Figure 38. Power Cable Pinout - DM991C/CE
Minimum
power (V)
Maximum
power (V)
AC 50~60 Hz
93
250
DC
36
72
Table 25. Power Input Range - DM991C/CE
The power supply, where the supply cable is connected, must be positioned near the equipment and be
on an easily accessible location, because the equipment is turned on and off through it
.
In case of using DC voltage, you must be careful so that the equipment protection earth cable (green
cable with yellow line related to the central socket pin) matches the system protection earth cable. This
cable must be connected before any other connection.
The equipment supports an 1A fuse, type T (delay), 250 V. If necessary, replace it only for another one of
the same type and value.
To prevent risks of electric shock, before opening the DM991C/CE equipments, disconnect the power
supply.
Summary of Contents for DM991C
Page 1: ...DM991 SERIES V DM991C DM991CE DM991S DM991SE PRODUCT MANUAL 204 4092 08 rev 08 Date 8 12 2008 ...
Page 66: ...Product Manual DM991 Series V Family 204 4092 08 66 Figure 31 LDL Test Converter Mode ...
Page 89: ...Phone 55 51 3358 0100 Support 55 51 3358 0122 Fax 55 51 3358 0101 www datacom ind br ...