8.12. DIPs Summary
DIP
Function
OPERATION
POSITION
A1 to A5 Speed selection
Table
See table
⊥
Internal
OFF / ON
External
ON / OFF *
Regenerated
OFF / OFF
External RX
ON / ON
Accepts
ON
Does not
accept
OFF*
Enabled
ON
Disabled
OFF*
Enabled
ON
Disabled
OFF*
Enabled
ON
DIsabled
OFF*
V.35
ON*
G.703
OFF
LTU
ON*
NTU
OFF
Management
ON
Dip-Switches
OFF*
Enabled
ON*
disabled
OFF
Enabled
ON
disabled
OFF*
Enabled
ON*
disabled
OFF
B8
▼
4W Operation
Converter Mode
#
B5
Terminal type
B6
Configuration
B7
◊
Ethernet
◊
B3
<<
CRC4
B4
†
Interface
B1
<<
Cross-Connect CAS
B1
<<
Timeslot 16
A6/A7
Transmissio clock
A8
LDR request
Table 18. DM991S/SE – DIPs Summary
⊥
See Table 16.
* Factory standard position
† This DIP loses purpose when DIP B7 is se to ON.
◊
Only for DM991SE model.
# Only for DM991S model
▼
Only for modems that works on four wires (4W).
<<These DIPs have no function when DIP B4 is ON and DIP B7 is OFF.
The DM991SE modems leave factory configured to internal transmission clock (A6=OFF/A7=ON)