8.8. Terminal type (DIP B5)
When ON, configures the modem as STU-C or LTU.
When OFF, configures the modem as STU-R or NTU.
When the modem is configured as NTU, DIPs A1-A5 determines the transmission rate of the interface
selected by B4.
When the modem is configured in LTU, the frame mode is plesiochronous and the annex is automatic (in
relation to the DIP-switches configuration). If other frame mode or annex is wished, it is necessary to do
the configuration through the terminal.
This DIP has no function when DIP B7 is set to ON, that is, converter mode enabled.
8.9. Configuration (DIP B6)
When ON, enables the configuration functions and modem loopback tests by the manager or the terminal.
When OFF, the equipment configuration is given by the configuration of the other DIP-switches.
When this DIP-switch is ON, the configuration will be determined by the management system. In case no
configuration has ever been done by the manager the DIP-Switches configuration will be used until the
management system programs a different configuration. To store the configuration done by the manager
in a non volatile (E2PROM), the request must be done via manager or terminal. This way, the equipment
can recover the configuration even after being shut off.
When OFF, it is possible to monitor the modem through the manager, but the configuration is inhibited.
The modem is then configured by the straps and DIP-switches.
8.10. Converter Mode / Ethernet interface enabling (DIP B7)
The DIP B7 presents different functions for modems DM991S and DM991SE:
8.10.1. DM991S
When ON, enables Converter Mode (Item 8.4).
8.10.2. DM991SE
When OFF, disables the Ethernet interface. In this case the active interface is selected through DIP B4.
When ON, enables the Ethernet interface. In this case, DIP B4 will be ignored and the only tributary
enabled will be the Ethernet. To enable the other tributaries simultaneously it is necessary to set the
configurations through the remote management or the terminal. For that, DIP B6 must be set to ON.
8.11. Four wire operation
Only for 4W modems.
When ON, the G.shdsl interface works over 4 wires.
When OFF, the G.shdsl interface works over 2 wires.
Summary of Contents for DM991C