TERMINAL MANAGEMENT
The DM991 family modems can be configured through a VT100 terminal (or an emulator of a PC Terminal
such as the Windows
HyperTerminal
) connected to the Terminal port in the front panel.
The Terminal should be configured for 9600bit/s without flow control, 1 stop bit and without parity bit.
When configured with Windows2000
, it is recommended not to use the HyperTerminal
, for it presents
some problems working on this platform. For that, it is recommended to use the TeraTerm
, which is
freeware and can be acquired at the following web address:
http://www.vector.co.jp/authors/VA002416/teraterm.html
As soon as the connection is established, the terminal might ask for an access password, which is factory
configured as “admin” (this password will only be requested if the user configures the equipment to do so).
This password can be changed or even disabled as will bee seen next.
The terminal has a 10 minute timeout, in a way that if nothing is typed in that time, it returns to the
password identification screen. Bellow are described the configuration and management menus.
#
--------------------------------------------------------------------------
#
D A T A C O M
#
DM991C - G.SHDSL Modem - E1 and V.35 Interfaces
#
--------------------------------------------------------------------------
#
#
1 - Choose equipment to configure
#
2 - Equipment information
#
3 - Terminal access password configuration
#
4 - Change terminal language
#
#
E - Exit
#
R - Exit and reset
#
#
#
#
#
#
#
Option: [ ]
#
#
#
--------------------------------------------------------------------------
#
www.datacom.ind.br
#
--------------------------------------------------------------------------
The options on this screen are:
•
1 - Choose equipment: accesses the configuration menu for the interfaces, making it
possible to chose between configuring the equipment local or remotely.
•
2 - Equipment configuration: informs the factory default parameters and detailed
information on the equipment.
•
3 - Password configurations: allows the terminal access password to be configured,
altered or disabled.
•
4 - Change terminal language: allows changing the terminal language to English or
Portuguese.
•
E - Exit: The “Exit” option is used to finalize the terminal access, returning to the access
password screen, so new configurations can only be done providing the right password is
informed once more, when the password request option is enabled.
Summary of Contents for DM991C
Page 1: ...DM991 SERIES V DM991C DM991CE DM991S DM991SE PRODUCT MANUAL 204 4092 08 rev 08 Date 8 12 2008 ...
Page 66: ...Product Manual DM991 Series V Family 204 4092 08 66 Figure 31 LDL Test Converter Mode ...
Page 89: ...Phone 55 51 3358 0100 Support 55 51 3358 0122 Fax 55 51 3358 0101 www datacom ind br ...