![Datacom DM991C Product Manual Download Page 54](http://html.mh-extra.com/html/datacom/dm991c/dm991c_product-manual_511542054.webp)
Product Manual - DM991 Series V Family - 204.4092.08
54
10.6.1. G.shdsl Interface Test Menu
#
--------------------------------------------------------------------------
#
D A T A C O M [ 1 ]
#
DM991C - G.SHDSL Modem - E1 and V.35 Interfaces
#
--------------------------------------------------------------------------
#
G.SHDSL Tests
#
#
1 - Stop testing
#
2 - Start LDL test
#
3 - Start LAL test
#
4 - Start RDL test
#
5 - Start BERT test
#
6 - Insert BERT error
#
7 - Reset BERT counters
#
#
#
#
#
Current test status :[ Not running ]
#
#
Option: [ ]
#
#
--------------------------------------------------------------------------
#
<P>revious <ESC> Exit <ENTER> Refresh <N>ext
#
--------------------------------------------------------------------------
•
1 - Stop testing: disables the current test.
•
2 - LDL: starts LDL tes.
•
3 - LAL: activates LAL test, (can only be run in the local equipment).
•
4 - LDR: starts LDR test.
•
5 - Initiate BERT sequence: activates BERT test.
•
6 - Insert BERT error: generates bit error in the BERT sequence being transmitted.
•
7- Reset BERT counters: resets counters of total time and test error time.
10.6.2. Digital Interface Test Menu
#
--------------------------------------------------------------------------
#
D A T A C O M [ 1 ]
#
DM991C - G.SHDSL Modem - E1 and V.35 Interfaces
#
--------------------------------------------------------------------------
#
V.35 Tests
#
#
1 - Stop testing
#
2 - Start LDL test
#
#
#
#
#
#
#
#
#
#
Current test status :[ Unavailable ]
#
#
Option: [ ]
#
#
--------------------------------------------------------------------------
#
<P>revious <ESC> Exit <ENTER> Refresh <N>ext
#
--------------------------------------------------------------------------
•
1 - Stop testing: disables the current test.
•
2 - LDL: activates LDL test.
Summary of Contents for DM991C
Page 1: ...DM991 SERIES V DM991C DM991CE DM991S DM991SE PRODUCT MANUAL 204 4092 08 rev 08 Date 8 12 2008 ...
Page 66: ...Product Manual DM991 Series V Family 204 4092 08 66 Figure 31 LDL Test Converter Mode ...
Page 89: ...Phone 55 51 3358 0100 Support 55 51 3358 0122 Fax 55 51 3358 0101 www datacom ind br ...