Product Manual - DM991 Series V Family - 204.4092.08
49
10.5.2. G.shdsl Interface Configuration Menu
#
--------------------------------------------------------------------------
#
D A T A C O M [ 1 ]
#
DM991C - G.SHDSL Modem - E1 and V.35 Interfaces
#
--------------------------------------------------------------------------
#
G.SHDSL Configuration
#
#
Enable Operation :[ Yes ]
#
Enable tests :[ Yes ]
#
Enable RDL reception :[ Yes ]
#
Number of channels :[ 32 ]
#
Remote management :[ Use EOC bits ]
#
Unit type :[ NTU ]
#
Annex :[ Automatic ]
#
Frame mode :[ Automatic ]
#
Line Operation :[ 2 Wires ]
#
#
#
#
#
#
#
--------------------------------------------------------------------------
#
<P>revious <ESC> Exit <ENTER> Save and Exit <TAB> Change <N>ext
#
--------------------------------------------------------------------------
•
Enable Operation: enables or disables the interface, when disabled the modem to take on
Converter Mode.
•
Enable tests: enables the test activation on this interface through the test menu or through
the management.
•
Enable RDL reception: informs if the interface should recognize and accept the LDR
request, through the remote modem and go into loop.
•
Number of channels: It can range from 1 to 36 2-wire channels and 1 to 72 4-wire
channels.
•
Remote management: Allows to configure the G.shdsl interface management channel or
to disable it.
•
Operation mode: determines if the modem operates as LTU (central) or as NTU (user).
•
Annex : Can be configured as annex A, B or automatic selection.
•
Frame mode: selects synchronous, plesiochronous or automatic mode.
•
Line Operation: Enables operation in the line, on 2 wires or 4 wires.
This option is available only for models DM991S and DM991C. In order to disable the G.shdsl interface,
you have to enable the destructive settings in the general equipment settings menu.
Only for 4W models.
Summary of Contents for DM991C
Page 1: ...DM991 SERIES V DM991C DM991CE DM991S DM991SE PRODUCT MANUAL 204 4092 08 rev 08 Date 8 12 2008 ...
Page 66: ...Product Manual DM991 Series V Family 204 4092 08 66 Figure 31 LDL Test Converter Mode ...
Page 89: ...Phone 55 51 3358 0100 Support 55 51 3358 0122 Fax 55 51 3358 0101 www datacom ind br ...