![Datacom DM991C Product Manual Download Page 59](http://html.mh-extra.com/html/datacom/dm991c/dm991c_product-manual_511542059.webp)
Product Manual - DM991 Series V Family - 204.4092.08
59
10.7.5. Bridge Interface Status Menu
#
--------------------------------------------------------------------------
#
D A T A C O M [ 1 ]
#
DM991CE - G.SHDSL Modem With Ethernet Bridge
#
--------------------------------------------------------------------------
#
Bridge Status
#
#
Operation :[ Active ]
#
Link :[ No Link ]
#
Auto Negotiation :[ Unavailable ]
#
#
#
#
#
#
#
#
#
#
#
#
#
--------------------------------------------------------------------------
#
<P>revious <ESC> Exit <ENTER> Refresh <N>ext
#
--------------------------------------------------------------------------
•
Operation: indicates if the interface is active.
•
Link: indicates if there is synch on the interface.
•
Auto negotiation: indicates if the equipment connected using full-duplex mode or half-
duplex mode.
10.8. Performance Menu
On this menu the following G.shdsl interface performance information are available.
Pressing ENTER, the information will be updated. The key "R" restarts the performance counters.
#
--------------------------------------------------------------------------
#
D A T A C O M [ 1 ]
#
DM991C - G.SHDSL Modem - E1 and V.35 Interfaces
#
--------------------------------------------------------------------------
#
G.SHDSL Performance
#
#
Code violations (CV) :[ 0 ]
#
Errored seconds (ES) :[ 0 ]
#
Severely errored seconds (SES) :[ 0 ]
#
LOSW seconds (LOSWS) :[ 0 ]
#
Unavailable seconds (UAS) :[ 0 ]
#
Loop attenuation (dB) :[ Not trained ]
#
Signal quality (dB) :[ Not trained ]
#
Time since last counters reset (s):[ 7741 ]
#
#
#
#
#
#
#
#
--------------------------------------------------------------------------
#
<ESC> Back <ENTER> Refresh <R>eset Counters
#
--------------------------------------------------------------------------
•
Code Violation (CV): CRC errors counter on the G.shdsl interface occurred during a
accumulated period.
•
Errored Seconds (ES): counter of 1 second intervals during which one or more anomalies
on the CRC and/or one or more LOSW defects are verified.
•
Severely Errored Seconds (SES): counter of 1 second intervals during which at least 50
anomalies on the CRC or one or more LOSW defects happen.