VS-10XX-F, VS-11XX-F, VS-12XX-F FASTstart Guide

 

3.

 

A port group must be created consisting of the 4 ports that are connected to the Intrusion 
Detection Systems (IDS). 

 

Command 

Description 

create group output_ports 

Creates a port group named “output_ports”. 

add group member output_ports 2,3,4,5  

Adds ports 2, 3, 4, and 5 to the group. 

show group output_ports  

Shows the details for the group “output_ports”. 

 
 

4.

 

A load balancing configuration must be created to load balance traffic from the Tapped link to 
the 4 IDSs.  

 

Command 

Description 

create lbc LBC1 

Creates a LBC named “LBC1”. 

set lbc ingress-ports LBC1 1 

Sets port 1 as the ingress port for” LBC1”. 

set lbc egress-ports LBC1 output_ports 

Sets the port group “output_ports” as the egress 
ports in LBC “LBC1”. 

set lbc state LBC1 active 

Activates the load balance group to start passing 
traffic. 

 
 

Traffic from the Tapped link will now be load balanced to the 4 IDSs. The 1G monitoring 
devices are able to share the traffic coming in from the 10G link. This allows them to not 
become oversubscribed with traffic. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for VS-1012-F

Page 1: ...VS 1012 F VS 1024 F VS 1112 F VS 1124 F VS 1212 F VS 1224 F Network Packet Brokers FASTstart Guide December 2015 2015 Datacom Systems Inc ...

Page 2: ...P Transceivers 7 2 4 Front Any to Any Ports 7 2 5 Front Power Status Indicators 8 2 6 Front Display and Buttons 8 2 7 Rear Power Module 9 2 8 Rear Management Module 9 3 Network IP Address Configuration 10 3 1 Default Settings 10 3 2 Setting up the VERSAstream for Management Port Access 11 4 Management Connection 13 4 1 Setup 13 4 2 Connecting via Telnet SSH 14 4 3 Web Browser 17 5 Configuration Ex...

Page 3: ...stems Inc products you agree to the terms set forth No licenses express or implied are granted with respect to the technology described and Datacom Systems Inc retains all rights with respect to the technology described herein If applicable you may return the product to the place of purchase for a full refund 1 3 Proprietary Notice This document contains proprietary information about the VS 1012 F...

Page 4: ...ible with the maximum ambient temperature specified B Reduced Air Flow Installation ofthe equipment in a rack should be such that the amount of air flow required for safe operation ofthe equipment is not compromised C MechanicalLoading Mounting ofthe equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanicalloading D Circuit Overloading Consideration s...

Page 5: ... Packet Broker filtering and load balancing functionality allows you to lighten the load to your network analyzers probes and security equipment by allowing you to filter only the data you want to monitor and distribute it among the tools evenly Greater selectivity and visibility accelerates problem resolution reduces downtime and increases enterprise productivity Like all Datacom Systems Data Acc...

Page 6: ...1XX F and VS 12XX F models support SFP Management Port rear RJ45 10 100 1000 Mb Full Duplex Serial Port rear DB9 115 200 bps 8 data bits Parity none 1 stop bit Flow control none Input Power Requirement 100 240VAC 50 60Hz 4 0 2 0 A Dimensions H x W x D 1 72 x 19 00 x 20 50 inch 4 37 x 48 26 x 52 07 cm Weight 18 15 lbs 8 23 kg Operating Temperature 32º to 104 F 0º to 40 C Storage Temperature 22º to ...

Page 7: ...BASE LW FTLX1612M3BCL 10GBASE ER 10GBASE EW 10GBASE ER EW FEC FTLX1671D3BCL 10GBASE ER 10GBASE EW FTLX1811M3 10GBASE ZR 10GBASE ZW FTLX8511D3 10GBASE SR 10GBASE SW FTLX8512D3BCL 10GBASE SR 10GBASE SW FTLX8571D3BCL 10GBASE SR 10GBASE SW FTLX8571D3BCV 1000BASE SX 10GBASE SR 10GBASE SW 2 4 Front Any to Any Ports When receiving traffic the Any to Any ports on the front of the VERSAstream can be connec...

Page 8: ...ot a power supply connected or it is not switched ON Although only one power source is required to power the VERSAstream use of a second independent power source is strongly recommended to assure uninterrupted monitoring The STATUS LED indicator is orange during the boot up cycle and turns green upon a successful boot sequence indicating the VERSAstream is operational NOTE The STATUS LED indicator...

Page 9: ... and DC labels will illuminate green when a power supply is connected and switched ON If either LED is illuminated red it indicates a defective power source Immediate investigation is recommended to insure redundant power integrity 2 8 Rear Management Module The SERIAL 1 connector port is a shielded DB9 Female This port can be connected to the COM port of any compatible network tool or PC in order...

Page 10: ...a factory default configuration as follows IMPORTANT If you expect to remotely connect to the VERSAstream series you must change the IP Address Subnet Mask and Gateway to match your Local Area Network In order to initially change the IP settings on the management port you must connect to the device over the serial port SSH and Telnet Port 22 and 23 Serial Terminal Settings Bits per second 115200 D...

Page 11: ...roduct representative for available sources of a USB RS 232 Serial Adapter Step 2 Using the supplied AC Line Cord s plug the VERSAstream into an external power source Depress the AC power switch bar icon to power ON the VERSAstream which will be soon followed by the internal cooling fans powering up Step 3 Open the terminal emulation application PuTTy or Tera Term for example on your PC and use it...

Page 12: ... o SET GATEWAY Gateway IP address o EXIT You must enter the exit command and log back into the VERSAstream before the changes are applied Step 6 Once you have logged back in to the device enter the show management command This will display setting information regarding the management port Verify that the settings are correct You may choose to configure the VERSAstream using either the serial port ...

Page 13: ... management port is connected directly to a laptop or PC a crossover cable may be required When the cable is connected the LED light on the left side of the port will illuminate green This indicates that a link has been established with the device on the other end of the cable The LED on the right side of the port will occasionally blink green when traffic is being passed To confirm that there is ...

Page 14: ...twork a terminal emulator may be used to configure the device The following steps show the process for connecting to the VERSAStream through either Telnet or SSH The images used in the steps are from the terminal emulator Tera Term Most terminal emulators can be used to connect to the VERSAStream however using either Tera Term or Putty is recommended Step 1 Open the terminal emulator Select either...

Page 15: ...ill pop up on the first connection attempt to the VERSAStream from the terminal This is a security feature of SSH Click connect Step 3 You will be presented with login prompt This could appear in the form of a pop up window or a terminal depending on the terminal emulator used Default credentials are Administrator admin ...

Page 16: ... the correct device was made enter the show command to view unique identifiers for the unit such as the Serial Number and MAC Address Note For more information on CLI configuration download the VS 1012 1024 1112 1124 1212 1224 Command Line Manual from the website at http www datacomsystems com resources manuals ...

Page 17: ...b sessions are not supported and will be redirected to HTTPS To access the VERSAstream GUI first open a web browser Compatible web browsers include Google Chrome 35 Microsoft Internet Explorer 11 and Mozilla Firefox 33 Enter https followed by the IP address of the VERSAstream and hit Enter You may be brought to a screen that asks you to confirm that you know the destination address This will look ...

Page 18: ... Firefox Internet Explorer Next you will be brought to the GUI login screen Enter the login credentials Default is Administrator admin Click Log in Note Video guides for GUI configuration can be found at the bottom of the page at http www datacomsystems com resources manuals ...

Page 19: ... To set up the above configuration on a VERSAstream the first step is to install the correct SFP types to connect to the devices on either end 2 The next step is to configure the ports on the device to match the speed of the devices connected to them For example choosing between Auto Negotiation copper or manually set speed Command Description set port speed 1 5 10G Sets ports 1 and 5 to 10G Fiber...

Page 20: ...5 show port routing Displays all traffic steering configurations The speed and media type of traffic will now be converted by the VERSAstream This gave the monitors access to data streams that were in a previously incompatible format 5 2 Aggregation Use Case There are multiple SPAN and TAP inputs and a single 1G or 10G monitor Traffic needs to be taken from the SPAN and TAP inputs and combined int...

Page 21: ...o 10G Fiber speed set port speed 3 1000X Manual Sets ports 3 to 1G Fiber speed show port config 1 5 Displays the configured speeds for ports 1 5 3 Finally Port Steering must be set up on the configuration of the device to direct traffic flow from the inputs to the output Command Description set port monitor 5 from 1 2 3 4 Directs traffic incoming from ports 1out port 5 show port routing Displays a...

Page 22: ...tection Systems IDS 1 To set up the above configuration on a VERSAstream the first step is to install the correct SFP types to connect to the devices on either end 2 The next step is to configure the ports on the device to match the speed of the devices connected to them For example choosing between Auto Negotiation copper or manually set speed Command Description set port speed 1 10G Sets ports 1...

Page 23: ...balancing configuration must be created to load balance traffic from the Tapped link to the 4 IDSs Command Description create lbc LBC1 Creates a LBC named LBC1 set lbc ingress ports LBC1 1 Sets port 1 as the ingress port for LBC1 set lbc egress ports LBC1 output_ports Sets the port group output_ports as the egress ports in LBC LBC1 set lbc state LBC1 active Activates the load balance group to star...

Page 24: ...bove configuration on a VERSAstream the first step is to install the correct SFP types to connect to the devices on either end 2 The next step is to configure the ports on the device to match the speed of the devices connected to them For example choosing between Auto Negotiation copper or manually set speed Command Description set port speed 1 2 5 10G Sets ports 1 2 and 5 to 10G Fiber speed set p...

Page 25: ...the ports connected to the monitors Command Description add filter IP1 ip src 192 168 1 20 Creates a filter that only allows the IP address of 192 168 1 20 and names it IP1 add filter IP2 ip dst 192 168 1 25 Creates a filter that blocks traffic with the IP address of 192 168 1 25and names it IP2 set port filter 3 egress IP2 Sets the IP2 filter to all traffic leaving port 3 set port filter 4 egress...

Page 26: ...t Guide 6 Customer Service DatacomCustomer Service is available via telephone and Internet You mayalso find the assistance you need at our website http www datacomsystems com Telephone 1 315 463 9541 Internet website http www datacomsystems com support contact support ...

Page 27: ...27 VS 10XX F VS 11XX F VS 12XX F FASTstart Guide Datacom Systems Inc 9 Adler Drive East Syracuse NY 13057 TEL 1 315 463 9541 FAX 1 315 463 9557 http www datacomsystems com ...

Reviews: