20
VS-10XX-F, VS-11XX-F, VS-12XX-F FASTstart Guide
3.
Finally, Port-Steering must be set up on the configuration of the device to direct traffic flow
from the inputs to the outputs.
Command
Description
set port monitor 4 from 1
Directs traffic incoming from port 1 out port 4.
set port monitor 5 from 2,3
Directs traffic incoming from ports 2, 3 out port 5.
show port routing
Displays all traffic steering configurations.
The speed and media type of traffic will now be converted by the VERSAstream. This gave the
monitors access to data streams that were in a previously incompatible format.
5.2 Aggregation
Use Case:
There are multiple SPAN and TAP inputs and a single (1G or 10G) monitor. Traffic
needs to be taken from the SPAN and TAP inputs and combined into a single output link.
1.
To set up the above configuration on a VERSAstream, the first step is to install the correct SFP
types to connect to the devices on either end.
1
2
3
4
5