© 2015 Datacom Systems Inc
21
VS-10XX-F, VS-11XX-F, VS-12XX-F FASTstart Guide
2.
The next step is to configure the ports on the device to match the speed of the devices connected
to them (For example, choosing between Auto-Negotiation copper or manually set speed).
Command
Description
set port speed 1,4 CU-AUTO
Sets ports 1 and 4 to Auto copper speed.
set port speed 2,5 10G
Sets port 2 and 5 to 10G Fiber speed.
set port speed 3 1000X-Manual
Sets ports 3 to 1G Fiber speed.
show port config 1-5
Displays the configured speeds for ports 1-5.
3.
Finally, Port-Steering must be set up on the configuration of the device to direct traffic flow
from the inputs to the output.
Command
Description
set port monitor 5 from 1,2,3,4
Directs traffic incoming from ports 1out port 5.
show port routing
Displays all traffic steering configurations.
Traffic from each of the TAPS and SPAN ports will be combined and sent to the IDS. This
allowed a single IDS to monitor traffic from many different sources.