Chapter 2
22
Sync Signals
This section describes the following aspects of the sync signals:
• Sync source,
• Sync Sentinel, and
• Sync Master Mode.
Sync Source
To digitize the incoming video signal, the DT3152-LS frame grabber
board requires sync signals. Area-scan operations require both a
horizontal and a vertical sync signal. Line-scan operations require a
horizontal sync signal only; vertical sync signals are ignored.
illustrates the process of generating the horizontal and
vertical sync signals.
Figure 7: Horizontal and Vertical Sync Signals
video inputs
ADC
current input
composite
sync
source
threshold
extraction
variable-scan
edge
selection
composite,
variable-scan
h/v
external sync
specified input source
line-sync
timing
information
video to
digitize
frame sync
h/v
for
acquisition
Input
source
mux
&
source
video type