Principles of Operation
41
2
2
2
2
2
2
2
2
2
Note:
For line-scan operations, only the frame height and the frame
width are significant.
shows the settings you can program on a DT3152-LS board to
define the frame in area-scan mode.
Table 6: Frame Settings for the DT3152-LS Board in Area-Scan Mod e
Setting
Description
Range
Nominal
Values
Frame Left
The first pixel in the region
of interest, relative to the
first active pixel, to digitize.
0 to 4095
a
a. The granularity is 1.
0
Frame Width
The number of pixels per
line of video to digitize.
4 to 4096
b
pixels
b. The granularity is 4.
50 Hz: 768
60 Hz: 640
Frame Top
The first line of the region of
interest, relative to the first
active line, to digitize.
0 to 4095
a
lines
0
Frame Height
The number of lines per
frame of video (or
noninterlaced frame) to
digitize.
1 to 4096
a
lines
50 Hz: 576
60 Hz: 480