2 Safety Instructions
OM Hydraulic Aggregate, Version 1.0 01/2013
11
2.3
Safety Information for Certain Types of Use
2.3.1
Hazards caused by hot surfaces
Even after a short operation time or after longer idle times, the device parts
may become or still be hot.
In case of skin contact, serious burns may be incurred!
Note that during normal operation the hydraulic oil may reach a tempera-
ture of up to 80 °C!
Never open the screw connections of the hydraulic device parts that are
hot (or highly pressurised)!
Before starting work on hydraulic device parts, check whether you can
work safely at the given temperature! Before starting work on hydraulic
device parts, let them cool down sufficiently if need be!
Wear protective gear that is appropriate for all the work with or on the de-
vices!
2.3.2
Hazards caused by oil particles in the exhaust air
The exhaust air from the hydraulic aggregate with a pneumatic motor may
contain oil particles. The hydraulic aggregate with a pneumatic motor may
therefore only be operated outdoors or in very well ventilated rooms.
The requirements stated on the safety data sheet for the oil used in the oil
vaporiser must also be noted.
2.3.3
Hazards caused by misuse of cables
The cables or hoses for the electric power supply, pneumatic supply and hy-
draulics must not be used to move, lift or pull the device.
2.3.4
Hazards caused by unexpected actions
The device's electric motor and pneumatic motor has a lock. Should the sup-
ply energy fail, the undervoltage / vacuum monitoring shuts down the device.
The device cannot start up automatically because the system remains shut
down once the lock has engaged.