2 Safety Instructions
18
OM Hydraulic aggregate, Version 1.0 01/2013
2.5.3
Safety risk resulting from defective hydraulic hose maintenance
The hydraulic hoses must be replaced when the specified service life is
reached.
Regardless of the number of operating hours, have the hydraulic hoses re-
placed with new ones by the manufacturer or a person authorised by the
manufacturer every 6 years. The date of manufacture is printed on the hoses.
2.5.4
Safety risk resulting from insufficient separator check
All equipment for disconnecting from the energy supply should be checked
at an interval appropriate to the operating conditions.
These checks should involve comparing the actual effect with the described
process and effect. If variance is found, the error must be eliminated before
starting up again.
The devices feature equipment for disconnecting from the electric and / or
pneumatic energy supplies.
An electric main switch disconnects from the electric energy supply.
A ball cock disconnects from the pneumatic energy supply.
2.5.5
Safety risk resulting from insufficient electrical equipment check
Checks for electrical operating equipment are laid down by law. The operator
is responsible for compliance.
Destination in European Economic Area not defined:
The EP2 device is electric work equipment as defined in EC Directive "2009 / 104 /
EC concerning the minimum safety and health requirements for the use of work
equipment by workers at work".
It is therefore subject to mandatory periodic testing. Also observe the legal re-
quirements that apply at the operating site.
Applies to Germany only:
The EP2 device is electric work equipment as defined in EC Directive "2009 / 104 /
EC concerning the minimum safety and health requirements for the use of work
equipment by workers at work".
With regard to periodic testing, the requirements of the German "Ordinance on In-
dustrial Safety and Health (BetrSichV) § 10" and the requirements of the "Technical